DOI 10.1016/j.compbiomed.2020.104005

Медицинская библиотека · Computers in biology and medicine · 2020

In-silico pace-mapping using a detailed whole torso model and implanted electronic device electrograms for more efficient ablation planning.

Monaci Sofia, Strocchi Marina, Rodero Cristobal, Gillette Karli, Whitaker John, Rajani Ronak, Rinaldi Christopher A, O'Neill Mark, Plank Gernot, King Andrew, Bishop Martin J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Pace-mapping is a commonly used electrophysiological (EP) procedure which aims to identify exit sites of ventricular tachycardia (VT) by matching ventricular activation patterns (assessed by QRS morphology) at specific pacing locations with activation during VT. However, long procedure durations and the need for VT induction render this technique non-optimal. To demonstrate the potential of in-silico pace-mapping, using stored electrogram (EGM) recordings of clinical VT from implanted devices to guide pre-procedural ablation planning.

METHOD: Six scar-related VT episodes were simulated in a 3D torso model reconstructed from computed tomography (CT) imaging data, including three different infarct anatomies mapped from infarcted porcine imaging data. In-silico pace-mapping was performed to localise VT exit sites and isthmuses by using 12-lead electrocardiogram (ECG) signals and different combinations of EGM sensing vectors from implanted devices, through the creation of conventional correlation maps and reference-less maps.

RESULTS

Our in-silico platform was successful in identifying VT exit sites for a variety of different VT morphologies from both ECG correlation maps and corresponding EGM maps, with the latter dependent upon the number of sensing vectors used. We also showed the added utility of both ECG and EGM reference-less pace-mapping for the identification of slow-conducting isthmuses, uncovering the optimal algorithm parameters. Finally, EGM-based pace-mapping was shown to be more dependent upon the mapped surface (epicardial/endocardial), relative to the VT origin.

CONCLUSIONS

In-silico pace-mapping can be used along with EGMs from implanted devices to localise VT ablation targets in pre-procedural planning.

Для цитирования: Monaci Sofia, Strocchi Marina, Rodero Cristobal, Gillette Karli, Whitaker John, Rajani Ronak, Rinaldi Christopher A, O'Neill Mark, Plank Gernot, King Andrew, Bishop Martin J. In-silico pace-mapping using a detailed whole torso model and implanted electronic device electrograms for more efficient ablation planning.. Computers in biology and medicine. 2020. DOI: 10.1016/j.compbiomed.2020.104005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.