MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.26918

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2017

Comparison of two biodegradable-polymer-based sirolimus-eluting stents with varying elution and absorption kinetics in patients with acute myocardial infarction: A subgroup analysis of the PANDA III trial.

Guan Changdong, Xu Bo, Qiao Shubin, Qin Lei, Li Yi, Li Zhanquan, Guo Yong, Sun Zhongwei, Song Lei, Gao Runlin, PANDA III Investigators

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Implantation of early-generation metallic drug-eluting stents (DES) in patients with acute myocardial infarction (AMI) is associated with poor vessel wall healing. Use of biodegradable polymer (BP) DES might improve safety outcomes; however, the impact of varying drug elution and polymer absorption kinetics of BP-DES on clinical outcomes in the AMI population is unknown.

METHODS

This subgroup analysis of the randomized PANDA III trial included 732 patients (366 in each group) presenting with recent (<1 month) AMI. Primary endpoint was 1-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (MI), or ischemia-driven target lesion revascularization. Secondary endpoints included a patient-oriented composite endpoint (PoCE) of all-cause death, all MI, or any revascularization; individual TLF and PoCE components; and definite/probable stent thrombosis (ST).

RESULTS

There were no significant differences between-groups in baseline clinical, angiographic, or procedural characteristics other than the proportion of post-dilatation, which was performed more frequently with the BuMA stent (53.9% vs. 44.5%; P = 0.004). After 1 year, compared to Excel SES implantation in patients with AMI, BuMA was associated with similar incidences of TLF and PoCE (5.5% vs. 8.3%, P = 0.14; 8.8% vs. 9.9%, P = 0.61, respectively) but lower incidences of MI (2.5% vs. 6.1%, P = 0.02), target vessel MI (2.2% vs. 5.8%, P = 0.01), and definite/probable ST (0.3% vs. 2.2%, P = 0.04).

CONCLUSIONS

BuMA SES, with faster drug elution rate and polymer absorption kinetics, might improve safety outcomes compared to Excel SES in the high-risk AMI population. © 2017 Wiley Periodicals, Inc.

Для цитирования: Guan Changdong, Xu Bo, Qiao Shubin, Qin Lei, Li Yi, Li Zhanquan, Guo Yong, Sun Zhongwei, Song Lei, Gao Runlin, PANDA III Investigators. Comparison of two biodegradable-polymer-based sirolimus-eluting stents with varying elution and absorption kinetics in patients with acute myocardial infarction: A subgroup analysis of the PANDA III trial.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2017. DOI: 10.1002/ccd.26918.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.