MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hlc.2016.04.001

Медицинская библиотека · Heart, lung & circulation · 2016

Drug-eluting Balloon Versus Second Generation Drug Eluting Stents in the Treatment of In-stent Restenosis: A Systematic Review and Meta-analysis.

Liou Kevin, Jepson Nigel, Cao Chris, Luo Roger, Pala Sarvpreet, Ooi Sze-Yuan

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

BACKGROUND

In-stent restenosis (ISR) remains a significant mode of stent failure following PCI. The optimal treatment strategy, however, remains undefined and the role of drug-eluting balloons (DEB) in the management of ISR is also unclear.

METHODS

A meta-analysis was performed to compare the efficacy of DEB in the treatment of ISR against second generation drug eluting stents (DES).

RESULTS

Seven studies comprised of 1,065 patients were included for analysis. The follow-up period ranged from 12-25 months. The use of DEB was associated with an inferior acute gain in minimal luminal diameter (MLD) (0.36, 95% CI: 0.16-0.57mm), higher late loss in MLD (0.11, 0.02-0.19mm) and a higher binary restenosis rate at follow-up (risk ratio: 2.24, 1.49-3.37). No significant differences were noted in the overall incidence of the analysed clinical parameters between the two groups. When only the randomised controlled trials (RCT) were considered however, there was a strong trend towards higher target lesion revascularisation (TLR; 9.9% vs. 3.6%; RR: 2.5, p=0.07) and a significantly higher major adverse cardiovascular event (MACE) rate (15.7% vs. 8.8%; RR 1.78; p=0.02) with DEB.

CONCLUSION

While equipoise has been demonstrated in selected clinical outcomes between DEB and second generation DES in the treatment of ISR, the suboptimal angiographic outcome at follow-up and the higher TLR and MACE rates associated with DEB observed in the RCT are concerning. The results of the present analysis should be regarded as preliminary, although the generalised adoption of DEB in the treatment of ISR currently cannot be recommended.

Для цитирования: Liou Kevin, Jepson Nigel, Cao Chris, Luo Roger, Pala Sarvpreet, Ooi Sze-Yuan. Drug-eluting Balloon Versus Second Generation Drug Eluting Stents in the Treatment of In-stent Restenosis: A Systematic Review and Meta-analysis.. Heart, lung & circulation. 2016. DOI: 10.1016/j.hlc.2016.04.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.