BACKGROUND

The BASE ACS randomized trial demonstrated non-inferiority of titanium-nitride-oxide-coated bioactive stents (BAS), compared with everolimus-eluting stents (EES), for the primary endpoint of major adverse cardiac events (MACE) in patients presenting with acute coronary syndrome (ACS) at 12-month follow-up. We report the final long-term clinical outcome of the trial.

METHODS

We randomly assigned 827 patients with ACS to receive either BAS (417) or EES (410). The primary endpoint was MACE: a composite of cardiac death, non-fatal myocardial infarction (MI) or ischemia-driven target lesion revascularization (TLR) at 12-month follow-up. Analysis was performed by intention to treat. Follow-up was planned at 12months, and yearly thereafter through 7years.

RESULTS

Mean follow-up duration was 4.2±1.9years (median 5.0years). At 5-year follow-up, BAS was non-inferior to EES for the primary endpoint of MACE (14.4% versus 17.8%, respectively; hazard ratio for BAS versus EES, 0.82; 95% confidence interval, 0.58-1.16; p=0.26 for superiority; p<0.001 for non-inferiority). The rate of non-fatal MI was lower in the BAS group (5.9% versus 9.7%, respectively, p=0.028). The rates of cardiac death and ischemia-driven TLR were comparable (2.8% versus 3.8%, and 8.3% versus 9.9%; p=0.76 and p=0.58, respectively).

CONCLUSIONS

In the current final report of the randomized BASE ACS trial in patients with ACS, BAS implantation was associated with a rate of cumulative MACE at long-term follow-up that was statistically non-inferior to EES.

Для цитирования: Karjalainen Pasi P, Nammas Wail, Ylitalo Antti, de Bruyne Bernard, Lalmand Jacques, de Belder Adam, Rivero-Crespo Fernando, Kervinen Kari, Airaksinen Juhani K E. Long-term clinical outcome of titanium-nitride-oxide-coated stents versus everolimus-eluting stents in acute coronary syndrome: Final report of the BASE ACS trial.. International journal of cardiology. 2016. DOI: 10.1016/j.ijcard.2016.07.267.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.