MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lary.27683

Медицинская библиотека · The Laryngoscope · 2018

Predicting laryngeal exposure in microlaryngoscopy: External validation of the laryngoscore.

Tirelli Giancarlo, Gatto Annalisa, Fortunati Alfonso, Marzolino Riccardo, Giudici Fabiola, Boscolo Nata Francesca

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

Optimal laryngeal exposure during transoral laryngeal surgery is fundamental. We aimed to evaluate the reliability of a recently proposed score (Laryngoscore) in predicting difficult laryngeal exposure (DLE) in an independent cohort of patients undergoing elective microlaryngoscopy. We also verified the relation between DLE, surgeon's expertise, and difficult intubation, and investigated possible areas for score improvement.

STUDY

DESIGN

Prospective validation study.

METHODS

A total of 136 patients were preoperatively evaluated using the Laryngoscore. Patients were divided into three classes according to patient position, type of laryngoscope, and need for external counterpressure to expose the anterior commissure. Based on their mean scores, two groups were identified: good laryngeal exposure (GLE) and DLE. A receiver operating characteristic curve with the Youden index was used to calculate the optimal cutoff value. The χ2 and Fisher exact test were used to correlate GLE and DLE to the surgeon's expertise and difficult intubation. The intraoperative anatomical parameters underlying DLE were also recorded.

RESULTS

The optimal cutoff value for differentiating GLE and DLE was 4, which identified 80.6% of DLE cases. No statistically significant difference in GLE and DLE distribution was found between surgeons (P = 0.43). The correlation between difficult intubation and DLE was statistically significant (P = 0.03). The intraoperative parameters determining DLE were epiglottis characteristics (floppy, tight, or short), bulky abdomen and chest, bulky tongue base, mobile teeth, and a narrow laryngeal aditus.

CONCLUSION

The Laryngoscore is reliable for detecting DLE preoperatively. The inclusion of additional parameters may allow a more complete assessment and maximize its diagnostic accuracy.

LEVEL OF EVIDENCE: 2b Laryngoscope, 129:1438-1443, 2019.

Для цитирования: Tirelli Giancarlo, Gatto Annalisa, Fortunati Alfonso, Marzolino Riccardo, Giudici Fabiola, Boscolo Nata Francesca. Predicting laryngeal exposure in microlaryngoscopy: External validation of the laryngoscore.. The Laryngoscope. 2018. DOI: 10.1002/lary.27683.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.