Effects of individualised positive end-expiratory pressure titration on respiratory and haemodynamic parameters during the Trendelenburg position with pneumoperitoneum: A randomised crossover physiologic trial.

Boesing Christoph, Schaefer Laura, Schoettler Jochen Johannes, Quentin Alena, Beck Grietje, Thiel Manfred, Honeck Patrick, Kowalewski Karl-Friedrich, Pelosi Paolo, Rocco Patricia R M, Luecke Thomas, Krebs Joerg

Рандомизированное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The Trendelenburg position with pneumoperitoneum during surgery promotes dorsobasal atelectasis formation, which impairs respiratory mechanics and increases lung stress and strain. Positive end-expiratory pressure (PEEP) can reduce pulmonary inhomogeneities and preserve end-expiratory lung volume (EELV), resulting in decreased inspiratory strain and improved gas-exchange. The optimal intraoperative PEEP strategy is unclear.

OBJECTIVES

To compare the effects of individualised PEEP titration strategies on set PEEP levels and resulting transpulmonary pressures, respiratory mechanics, gas-exchange and haemodynamics during Trendelenburg position with pneumoperitoneum.

DESIGN

Prospective, randomised, crossover single-centre physiologic trial.

SETTING

University hospital.

PATIENTS: Thirty-six patients receiving robot-assisted laparoscopic radical prostatectomy.

INTERVENTIONS: Randomised sequence of three different PEEP strategies: standard PEEP level of 5 cmH 2 O (PEEP 5 ), PEEP titration targeting a minimal driving pressure (PEEP ΔP ) and oesophageal pressure-guided PEEP titration (PEEP Poeso ) targeting an end-expiratory transpulmonary pressure ( PTP ) of 0 cmH 2 O.

MAIN OUTCOME MEASURES: The primary endpoint was the PEEP level when set according to PEEP ΔP and PEEP Poeso compared with PEEP of 5 cmH 2 O. Secondary endpoints were respiratory mechanics, lung volumes, gas-exchange and haemodynamic parameters.

RESULTS

PEEP levels differed between PEEP ΔP , PEEP Poeso and PEEP5 (18.0 [16.0 to 18.0] vs. 20.0 [18.0 to 24.0]vs. 5.0 [5.0 to 5.0] cmH 2 O; P  < 0.001 each). End-expiratory PTP and lung volume were lower in PEEP ΔP compared with PEEP Poeso ( P  = 0.014 and P  < 0.001, respectively), but driving pressure, lung stress, as well as respiratory system and dynamic elastic power were minimised using PEEP ΔP ( P  < 0.001 each). PEEP ΔP and PEEP Poeso improved gas-exchange, but PEEP Poeso resulted in lower cardiac output compared with PEEP 5 and PEEP ΔP .

CONCLUSION

PEEP ΔP ameliorated the effects of Trendelenburg position with pneumoperitoneum during surgery on end-expiratory PTP and lung volume, decreased driving pressure and dynamic elastic power, as well as improved gas-exchange while preserving cardiac output.

TRIAL REGISTRATION: German Clinical Trials Register (DRKS00028559, date of registration 2022/04/27). https://drks.de/search/en/trial/DRKS00028559.

Для цитирования: Boesing Christoph, Schaefer Laura, Schoettler Jochen Johannes, Quentin Alena, Beck Grietje, Thiel Manfred, Honeck Patrick, Kowalewski Karl-Friedrich, Pelosi Paolo, Rocco Patricia R M, Luecke Thomas, Krebs Joerg. Effects of individualised positive end-expiratory pressure titration on respiratory and haemodynamic parameters during the Trendelenburg position with pneumoperitoneum: A randomised crossover physiologic trial.. European journal of anaesthesiology. 2023. DOI: 10.1097/eja.0000000000001894.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.