MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00405-024-09018-9

Медицинская библиотека · European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2024

Conventional one-handed compared to two-handed endoscopic ear surgery using an endoscope holder: a single center study.

Müller Christoph, Raczynski Anastasia, Lailach Susen, Zahnert Thomas

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

One-handedness is a challenge in conventional endoscopic ear surgery (EES). We present results on the first-ever application of the passive endoscope holder 'Endofix exo' (Co. AKTORmed GmbH, Neutraubling, Germany) in EES, which enables two-handed surgery.

METHODS

This two-sided study compares cut-suture time, operating time, postoperative complications, graft take rates, hearing results and quality of life in patients who underwent first stage tympanoplasty due to tympanic membrane perforation with intact ossicular chain conditions. 25 patients received classic EES (EES-, mean age: 28 ± 21 years) and 15 received EES with the passive holder (EES+, mean age: 48 ± 21 years).

RESULTS

Mean operating times (EES-: 96 ± 38 (SD) min; EES+: 107 ± 33 min), cut-suture times (EES-: 68 ± 30 min; EES+: 73 ± 31 min), complications, graft take rates and hearing results (preoperative air bone gap (ABG) (PTA4): 15 dB ± SD 8 dB (EES-); 16 dB ± SD 8 dB (EES+); postoperative ABG (PTA4): 11.25dB ± SD 11.3dB (EES-); 14 dB ± SD 10 dB (EES+)) did not differ significantly (p > 0.05) between the two groups. Postoperative hearing results and quality of life tended to improve in both groups (p > 0.05).

DISCUSSION: The passive endoscope holder has been successfully applied during the course of the study. However, modifications of the endoscope holder and further studies are recommended focusing on positioning of grafts and prostheses to obtain conclusive results regarding the superiority of two-handed EES over one-handed conventional EES.

Для цитирования: Müller Christoph, Raczynski Anastasia, Lailach Susen, Zahnert Thomas. Conventional one-handed compared to two-handed endoscopic ear surgery using an endoscope holder: a single center study.. European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery. 2024. DOI: 10.1007/s00405-024-09018-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.