DOI 10.1016/j.jjcc.2015.12.011

Медицинская библиотека · Journal of cardiology · 2016

Impact of final kissing balloon inflation on vessel healing following drug-eluting stent implantation: Insight from the optical coherence tomography sub-study of the J-REVERSE trial.

Takahashi Hachidai, Otake Hiromasa, Shinke Toshiro, Murasato Yoshinobu, Kinoshita Yoshihisa, Yamawaki Masahiro, Takeda Yoshihiro, Fujii Kenichi, Yamada Shin-Ichiro, Shimada Yoshihisa, Yamashita Takehiro, Yumoto Kazuhiko, Hirata Ken-Ichi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

We sought to clarify the impact of final kissing inflation (FKI) after single stenting of bifurcation lesions on vessel healing.

METHODS

From the J-REVERSE registry enrolling 303 bifurcation lesions treated with provisional single stenting using sirolimus- (SES) or everolimus-eluting stent (EES), 65 lesions treated with (n=30) and without (n=35) FKI underwent 9-month follow-up optical coherence tomography. Average stent eccentricity index (SEI: minimum/maximum stent diameter) and neointimal unevenness score (NUS: maximum/average neointimal thickness of the same cross-section) for the proximal, bifurcation, and distal segments were compared between FKI and non-FKI groups.

RESULTS

At the proximal segment, the FKI group demonstrated significantly larger average stent area with greater asymmetric stent expansion, and average lumen area remained significantly larger at 9-month follow-up despite a tendency toward greater neointimal proliferation. Jailed strut and thrombus incidence were also significantly lower at the side branch orifice, and NUS was significantly smaller at the bifurcation and proximal segments in the FKI group.

CONCLUSIONS

Nine months after SES and EES treatment of bifurcation lesions, FKI reduced proximal-segment luminal narrowing. Considering its homogeneous neointimal distribution and fewer jailed struts, FKI may be beneficial for treating bifurcation lesions.

Для цитирования: Takahashi Hachidai, Otake Hiromasa, Shinke Toshiro, Murasato Yoshinobu, Kinoshita Yoshihisa, Yamawaki Masahiro, Takeda Yoshihiro, Fujii Kenichi, Yamada Shin-Ichiro, Shimada Yoshihisa, Yamashita Takehiro, Yumoto Kazuhiko, Hirata Ken-Ichi. Impact of final kissing balloon inflation on vessel healing following drug-eluting stent implantation: Insight from the optical coherence tomography sub-study of the J-REVERSE trial.. Journal of cardiology. 2016. DOI: 10.1016/j.jjcc.2015.12.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.