MedElevator Войти в исследования
← Поиск публикаций

DOI 10.31616/asj.2022.0451

Медицинская библиотека · Asian spine journal · 2024

Correlation between the maximum standard uptake value and mean Hounsfield unit on single-photon emission computed tomography-computed tomography to discriminate benign and metastatic lesions among patients with breast cancer.

Saminathan S Thadchaiani, Ahmed Wan Aireene Wan, Nawi Norazlina Mat, Tagiling Nashrulhaq, Aziz Ilyana, Udin Yusri, Rohani Mohd Fazrin Mohd, Zainon Wan Mohd Nazlee Wan, Razab Mohammad Khairul Azhar Abdul

СтатьяПеревод пока не подготовлен

Аннотация

STUDY

DESIGN

Retrospective study.

PURPOSE: To compare and correlate technetium-99m methylene diphosphonate uptake between benign and metastatic bone lesions using semiquantitative analysis of maximum standard uptake value (SUVmax) and mean Hounsfield unit (HU) in single-photon emission computed tomography-computed tomography (SPECT-CT).

OVERVIEW OF LITERATURE: Qualitative interpretation of metastatic bone lesions in breast cancer on bone scintigraphy is often complicated by coexisting benign lesions.

METHODS

In total, 185 lesions were identified on bone and SPECT-CT scans from 32 patients. Lesions were classified as metastatic (109 sclerotic lesions) and benign (76 lesions) morphologically on low-dose CT. Semiquantitative analysis using SUVmax and mean HU was performed on the lesions and compared. To discriminate benign and metastatic lesions, the correlation between SUVmax and mean HU was determined using the intraclass correlation coefficients.

RESULTS

The SUVmax was higher in metastatic lesions (20.66±14.36) but lower in benign lesions (10.18±12.79) (p<0.001). The mean HU was lower in metastatic lesions (166.62±202.02) but higher in benign lesions (517.65±192.8) (p<0.001). A weak negative correlation was found between the SUVmax and the mean HU for benign lesions, and a weak positive correlation was noted between the SUVmax and the mean HU on malignant lesions with no statistical significance (p=0.394 and 0.312, respectively). The cutoff values obtained were 10.8 for SUVmax (82.6% sensitivity and 84.2% specificity) and 240.86 for the mean HU (98.7% sensitivity and 88.1% specificity) in differentiating benign from malignant bone lesions.

CONCLUSIONS

Semiquantitative assessment using SUVmax and HU can complement qualitative analysis. Metastatic lesions had higher SUVmax but lower mean HU than benign lesions, whereas benign lesions demonstrated higher mean HU but lower SUVmax. A weak correlation was found between the SUVmax and the mean HU on malignant and benign lesions. Cutoff values of 10.8 for the SUVmax and 240.86 for the mean HU may differentiate bone metastases from benign lesions.

Для цитирования: Saminathan S Thadchaiani, Ahmed Wan Aireene Wan, Nawi Norazlina Mat, Tagiling Nashrulhaq, Aziz Ilyana, Udin Yusri, Rohani Mohd Fazrin Mohd, Zainon Wan Mohd Nazlee Wan, Razab Mohammad Khairul Azhar Abdul. Correlation between the maximum standard uptake value and mean Hounsfield unit on single-photon emission computed tomography-computed tomography to discriminate benign and metastatic lesions among patients with breast cancer.. Asian spine journal. 2024. DOI: 10.31616/asj.2022.0451.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.