MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iop.0b013e3181994062

Медицинская библиотека · Ophthalmic plastic and reconstructive surgery · 2009

Rectangular 3-snip punctoplasty outcomes: preservation of the lacrimal pump in punctoplasty surgery.

Chak Melanie, Irvine Fiona

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report a method of rectangular 3-snip punctoplasty (2 vertical cuts at either side of the vertical canaliculus and 1 cut at the base). Outcomes are compared with the more conventional and anatomically destructive 3-snip triangular punctoplasty (1 cut at the vertical canaliculus, 1 cut at the horizontal canaliculus, and 1 cut at the base).

METHODS

Retrospective review of all eyes undergoing 3-snip punctoplasty between January 1, 2003 and January 8, 2005.

RESULTS

Seventy-five patients were eligible for this study. One hundred eight eyes with patent punctum and lacrimal systems prior to surgery underwent punctoplasty (49 rectangular and 59 triangular punctoplasty). Follow-up of 8 days to 2.3 years (mean, 0.68 years). Ages ranged between 16.8 and 99.8 years (mean, 69.5 years). Forty-five patients (60%) were women. There was a trend for patients to be symptomatic postoperatively despite patent punctum and lacrimal systems following triangular (10 of 59, 16.9%) than those who underwent rectangular punctoplasty (5 of 49, 10.2%) although this difference was not significant (difference in proportions = 0.05; CI: -17.635 to 17.645; p = 0.99).

CONCLUSIONS

This study showed that there were more failures in eyes with triangular punctoplasty. Previous studies have shown that the punctae and canaliculi are important in normal lacrimal drainage. Rectangular punctoplasty is a simple, safe, and quick procedure that maintains the normal anatomy and physiology of the canalicular system, while maintaining a patent punctum and should be considered as a less destructive alternative to the traditional triangular punctoplasty.

Для цитирования: Chak Melanie, Irvine Fiona. Rectangular 3-snip punctoplasty outcomes: preservation of the lacrimal pump in punctoplasty surgery.. Ophthalmic plastic and reconstructive surgery. 2009. DOI: 10.1097/iop.0b013e3181994062.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.