MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jvca.2025.08.013

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2025

Practice Pattern Variability in the Use of Pulmonary Arterial Catheters in Cardiac Surgery.

MacKay Emily J, Zhang Bo, Beaty Joseph M, Devine Katelyn A, O'Reilly-Shah Vikas, Mathis Michael R, Szeto Wilson Y, Groeneveld Peter W, Augoustides John G

СтатьяНаблюдательное исследованиеМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To quantify intraoperative pulmonary arterial catheter (PAC) use during cardiac surgery and identify hospital-, anesthesiologist-, and patient-level factors associated with PAC utilization.

DESIGN

A cross-sectional, observational study using generalized logistic mixed models to examine variations in PAC use.

SETTING

Fifty-three US academic hospitals participating in the Multicenter Perioperative Outcomes Group (MPOG) national registry

PARTICIPANTS

145,343 adult patients undergoing cardiac surgery between January 1, 2016, and December 31, 2022.

INTERVENTION(S): Receipt of intraoperative PAC, defined by ≥60 minutes of physiologically plausible pulmonary arterial pressures.

MEASUREMENTS & MAIN

RESULTS

The primary outcome was PAC utilization. Mixed-effects logistic regression quantified fixed-effect predictors, and variation attributable to anesthesiologists and then to anesthesiologists nested within a hospital was characterized using median odds ratio (MOR). Of the 145,343 cardiac surgeries performed across 53 hospitals, 104,626 (72%) included PAC monitoring. PAC use varied widely across hospitals (0-98%) and across anesthesiologists (0-100%). PAC was used most frequently in heart transplants (94%) and lung transplants (87%) and least frequently in pulmonic valve procedures (30%). A patient's likelihood of receiving a PAC was influenced most strongly by hospital (MOR, 15.00; 95% confidence interval [CI], 8.98-28.32), with substantially less variation attributable to an anesthesiologist within the same hospital (MOR, 1.70; 95% CI, 1.61-1.81).

CONCLUSIONS

Intraoperative PAC monitoring is used in nearly three-quarters of cardiac surgeries at US academic centers, with hospital practice pattern the factor most closely associated with PAC utilization.

Для цитирования: MacKay Emily J, Zhang Bo, Beaty Joseph M, Devine Katelyn A, O'Reilly-Shah Vikas, Mathis Michael R, Szeto Wilson Y, Groeneveld Peter W, Augoustides John G. Practice Pattern Variability in the Use of Pulmonary Arterial Catheters in Cardiac Surgery.. Journal of cardiothoracic and vascular anesthesia. 2025. DOI: 10.1053/j.jvca.2025.08.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.