Radiation and environmental biophysics · 2026
Comparison of different quality factor models for space radiation protection.
СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Papadopoulos Alexis, Kyriakou Ioanna, Santin Giovanni, Nieminen Petteri, Pang Dalong, Li Weibo, Daglis Ioannis A, Incerti Sebastien, Emfietzoglou Dimitris
Аннотация
Space radiation is considered the biggest threat to astronauts’ health in long-duration space missions, where the main concern is the potential carcinogenic effects from the continuous exposure to Galactic Cosmic Rays (GCR). The quality factor ([Formula: see text]) of GCR presents the greatest uncertainty, complicating accurate risk assessment and the establishment of safe radiation exposure standards for astronauts in missions beyond low Earth orbit. This study uses a recently developed analytic microdosimetric model to calculate [Formula: see text] values for space radiation. The influence of different target sphere diameters is examined, and optimum values are suggested. The predictions of the new model are benchmarked against experimental animal and in vitro data for [Formula: see text] and [Formula: see text] as well as against different versions of NASA’s model, and the International Commission on Radiological Protection (ICRP) Publication 60 recommendations. The comparisons involve quality factor values for individual ions ([Formula: see text]) over the 1 MeV/u to 1 GeV/u energy range, as well as dose-averaged quality factor values for GCR ([Formula: see text]) for three space radiation environments (free space, Moon and Martian surface) and different shielding conditions (aluminium, polyethylene, and regolith of 0–20 g/cm2). The results of the present model reveal strong variations of [Formula: see text] (up to a factor of ~ 6) and [Formula: see text] (up to a factor of ~ 4) depending on the sphere diameter, with the values of 100 and 1000 nm yielding better agreement with experimental data. Interestingly, the [Formula: see text] values calculated for a 1,000 nm sphere diameter align with NASA’s 2012 model and ICRP Publication 60 recommendations, whereas the [Formula: see text] values for the 100 nm sphere diameter agree better with NASA’s most recent 2022 model.