Аннотация

STUDY

OBJECTIVE

Frequently, attempts to obtain catheter urine samples from infants are unsuccessful because of an empty bladder, with urinary catheterization failure rates reported up to 16%. We seek to validate a sonographic urinary bladder index that will identify patients for whom catheterization will be unsuccessful.

METHODS

We conducted a prospective, blinded, observational study enrolling a convenience sample of children younger than 2 years and undergoing urinary catheterization in an urban pediatric emergency department. Failure was defined as a catheterization result of less than 2 mL of urine. Urinary bladder index, a concept we created, is defined as the product of anteroposterior and transverse diameters, expressed in centimeters squared. Sensitivity and specificity were calculated with 95% confidence intervals (CIs).

RESULTS

Forty-four patients were enrolled, with a median age of 8 months (range 0.5 to 24 months) and median weight of 7.8 kg (range 1.7 to 17.7 kg). Four children urinated during the procedure and were excluded. Thirty-five had urinary bladder index greater than 2.4 cm2 (range 2.5 to 15.5 cm2 ). All were successfully catheterized. Four children had urinary bladder index less than 2.4 cm2 (range 0 to 1.2 cm 2 ). No adequate samples were obtained from those children. The bladder was not visualized at all in 1 child who was successfully catheterized. Sensitivity of the urinary bladder index to identify failure to obtain 2 mL of urine was 100% (4 of 4; 95% CI 40% to 100%), specificity was 97% (35 of 36; 95% CI 85% to 100%).

CONCLUSION

A urinary bladder index less than 2.4 cm2 appears to identify infants for whom urinary catheterization will be unsuccessful because of insufficient urine volume. Ultrasonographic evaluation with urinary bladder index measurement before catheterization may eliminate the incidence of failed procedures.

Для цитирования: Milling Truman J, Van Amerongen Robert, Melville Laura, Santiago Lucia, Gaeta Theodore, Birkhahn Robert, Melniker Lawrence. Use of ultrasonography to identify infants for whom urinary catheterization will be unsuccessful because of insufficient urine volume: validation of the urinary bladder index.. Annals of emergency medicine. 2005. DOI: 10.1016/j.annemergmed.2004.11.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.