DOI 10.1097/meg.0000000000001120
Split-dose bowel cleansing with picosulphate is safe and better tolerated than 2-l polyethylene glycol solution.
Аннотация
BACKGROUND
In physically less fit patients and patients requiring repeated exams, adequate bowel preparation for colonoscopy remains problematic, particularly because patients need to drink large volumes of unpleasant-tasting fluids. A further concern is potential unwarranted fluid shifts.
AIMS: This study aimed to compare the safety and burden of a small-volume sodium picosulphate/magnesium citrate preparation (SPS-MC) with a 2-l ascorbic-acid-enriched polyethylene glycol solution plus bisacodyl pretreatment (PEG-Asc+B).
PATIENTS AND
METHODS
Patients referred for colonoscopy were randomized to SPS-MC or PEG-Asc+B administered as a split-dose regimen. Patients received advice on the recommended 4-l SPS-MC and 2-l PEG-Asc+B fluid intake. Safety was assessed by blood sampling before and after the preparation and during a 30-day follow-up period. A questionnaire assessed tolerability and perceived burden of the preparation.
RESULTS
A total of 341 patients underwent colonoscopy. Blood sampling showed a slight but significant decrease in sodium, chloride and osmolality and increase in magnesium in the SPS-MC group and a decrease in bicarbonate in the PEG-Asc+B group. Hyponatraemia and hypermagnesaemia without clinical signs were observed in 16 (14 SPS-MC) and 13 SPS-MC patients, respectively. Patients reported significantly fewer physical complaints and a significantly higher completion rate with SPS-MC. Patients receiving SPS-MC rated the intake as being easier and better tasting. In the event of a repeat colonoscopy, 59.7% of patients in the PEG-Asc+B and 93.6% of patients in the SPS-MC group would opt for the same preparation again.
CONCLUSION
Despite electrolyte shifts, both SPS-MC and PEG-Asc+B appeared clinically safe. From a patient's perspective, a small-volume preparation formula such as SPS-MC is preferred, resulting in fewer physical complaints and greater ease of intake.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.