MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/02184923221147442

Медицинская библиотека · Asian cardiovascular & thoracic annals · 2022

Thoraflex Hybrid vs. AMDS: To replace the arch or to stent it in type A aortic dissection?

Al-Tawil Mohammed, Jubouri Matti, Tan Sven Zcp, Bailey Damian M, Williams Ian M, Mariscalco Giovanni, Piffaretti Gabrielle, Chen Edward P, Velayudhan Bashi, Mohammed Idhrees, Bashir Mohamad

ОбзорСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Acute type A aortic dissection (ATAAD) is a life-threatening medical emergency that requires urgent surgical intervention. The mainstay surgical approach to treating ATAAD with aortic arch involvement is total arch replacement (TAR). The frozen elephant trunk (FET) procedure involves TAR with hybrid endovascular stenting of the DTA in a single step using a hybrid prosthesis (HP). The prime example of a FET HP is Thoraflex Hybrid Prosthesis (THP). Another treatment option is the novel Ascyrus Medical Dissection Stent (AMDS) that is deployed as a non-covered stent along with the aortic arch as an adjunct to prior hemi-arch replacement.

AIMS: This comparative review highlights the clinical applications and outcomes of THP and AMDS in the treatment of ATAAD and discusses the main differences between both approaches.

METHODS

A comprehensive literature search was conducted using multiple electronic databases including PubMed, Google Scholar, Ovid, Scopus and Embase.

RESULTS

TAR with FET can be considered the superior approach to managing ATAAD with arch involvement relative to AMDS with hemi-arch replacement due to more optimal clinical outcomes. Upon comprehensively searching the literature, early mortality was substantially lower with FET ranging from 0-11% compared to 12.5-18.7% using AMDS, with more favourable long-term survival. The incidence of kidney injury and new stroke post-FET ranged from 3-20% and 5-16%, and 11-37.5% and 0-18.8% following AMDS implantation. However, evidence supporting the use of AMDS is extremely limited. Meanwhile, TAR with FET is a well-established and well-described procedure for ATAAD repair.

CONCLUSION

Despite the novel nature of AMDS, its clinical safety and effectiveness are yet to be proven. In conclusion, THP remains the best evidenced-based approach to treat ATAAD in this era.

Для цитирования: Al-Tawil Mohammed, Jubouri Matti, Tan Sven Zcp, Bailey Damian M, Williams Ian M, Mariscalco Giovanni, Piffaretti Gabrielle, Chen Edward P, Velayudhan Bashi, Mohammed Idhrees, Bashir Mohamad. Thoraflex Hybrid vs. AMDS: To replace the arch or to stent it in type A aortic dissection?. Asian cardiovascular & thoracic annals. 2022. DOI: 10.1177/02184923221147442.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.