MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2024.07.055

Медицинская библиотека · Journal of shoulder and elbow surgery · 2024

Isolated humeral distalization in reverse total shoulder arthroplasty: a biorobotic shoulder simulator study.

Zitnay Jared L, Stout Madelyn R, Percin Brittany, Tashjian Robert Z, Chalmers Peter N, Joyce Christopher D, Walch Gilles, Henninger Heath B

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Humeral distalization is inherent to reverse total shoulder arthroplasty (rTSA) and is often produced with concomitant humeral lateralization via the level of the humeral head cut, implant positioning, implant neck shaft angle, and polymer insert thickness. Biomechanical data on the isolated effects of humeral distalization remain limited but could be important to consider when optimizing postoperative rTSA shoulder function. This study investigated the effects of isolated humeral distalization on shoulder biomechanics using a biorobotic shoulder simulator.

METHODS

Eight fresh-frozen cadaveric shoulders were tested using custom polymer inserts that translated the bearing surface 0, +5, +10, and +15 mm along the humeral stem axis, producing isolated distalization without lateralization. Specimens underwent passive elevation in the scapular plane with a static scapula to assess glenohumeral range of motion. Scapular plane abduction motion trajectories were then performed, driven by previously collected scapulothoracic and glenohumeral kinematics from rTSA patients. The effect of isolated distalization on passive elevation was tested using mixed-effects linear regression and the effect on muscle force, joint reaction force, and muscle excursion during active scapular-plane abduction was tested using statistical parametric mapping random effects analysis.

RESULTS

Maximum passive scapular plane elevation increased with humeral distalization (4° per 5 mm distalization). During active elevation, deltoid and rotator cuff muscle forces, and joint reaction forces, increased up to 37% per 5 mm of distalization. Simulated deltoid muscle excursion was altered with increasing distalization but amounted to no more than 0.8 mm change from baseline per 5 mm of distalization. Rotator cuff muscles were consistently lengthened throughout abduction, up to 1.6 mm per 5 mm of distalization. These trends were observed across various patient motions.

CONCLUSIONS

Isolated humeral distalization caused dramatic increases in the muscle forces required to perform scapular-plane abduction. Joint reaction forces increased correspondingly. These results suggest that implant and surgical strategies to generate deltoid muscle tension without humeral distalization may promote better active range of motion and more durable long-term outcomes over approaches that rely on distalization.

Для цитирования: Zitnay Jared L, Stout Madelyn R, Percin Brittany, Tashjian Robert Z, Chalmers Peter N, Joyce Christopher D, Walch Gilles, Henninger Heath B. Isolated humeral distalization in reverse total shoulder arthroplasty: a biorobotic shoulder simulator study.. Journal of shoulder and elbow surgery. 2024. DOI: 10.1016/j.jse.2024.07.055.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.