MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1227/ons.0000000000000999

Медицинская библиотека · Operative neurosurgery (Hagerstown, Md.) · 2023

Surgical Characteristics of Intracranial Biopsy Using a Frameless Stereotactic Robotic Platform: A Single-Center Experience.

Kreatsoulas Daniel C, Vignolles-Jeong Joshua, Ambreen Yamenah, Damante Mark, Akhter Asad, Lonser Russell R, Elder J Bradley

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

Cranial robotics are a burgeoning field of neurosurgery. To date, all cranial robotic systems described have been computerized, arm-based instruments that take up significant space in the operating room. The Medtronic Stealth Autoguide robot has a smaller operating room footprint and offers multiaxial, frame-based surgical targeting. The authors set out to define the surgical characteristics of a novel robotic platform for brain biopsy in a large patient cohort.

METHODS

Patients who underwent stereotactic biopsy using the Stealth Autoguide cranial robotic platform from July 2020 to March 2023 were included in this study. Clinical, surgical, and histological data were collected and analyzed.

RESULTS

Ninety-six consecutive patients (50 female, 46 male) were included. The mean age at biopsy was 53.7 ± 18.0 years. The mean target depth was 68.2 ± 15.3 mm. The biopsy diagnostic tissue acquisition rate was 100%. The mean time from incision to biopsy tissue acquisition was 15.4 ± 9.9 minutes. Target lesions were located throughout the brain: in the frontal lobe (n = 32, 33.3%), parietal lobe (n = 21, 21.9%), temporal lobe (n = 22, 22.9%), deep brain nuclei/thalamus (n = 13, 13.5%), cerebellum (n = 7, 7.3%), and brainstem (n = 1, 1.0%). Most cases were gliomas (n = 75, 78.2%). Patients were discharged home on postoperative day 0 or 1 in 62.5% of cases. A total of 7 patients developed postoperative complications (7.2%).

CONCLUSION

This cranial robotic platform can be used for efficient, safe, and accurate cranial biopsies that allow for reliable diagnosis of intracranial pathology in a minimally invasive setting.

Для цитирования: Kreatsoulas Daniel C, Vignolles-Jeong Joshua, Ambreen Yamenah, Damante Mark, Akhter Asad, Lonser Russell R, Elder J Bradley. Surgical Characteristics of Intracranial Biopsy Using a Frameless Stereotactic Robotic Platform: A Single-Center Experience.. Operative neurosurgery (Hagerstown, Md.). 2023. DOI: 10.1227/ons.0000000000000999.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление