MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1526602816657087

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2016

Multilayer Flow Modulator Treatment of Abdominal and Thoracoabdominal Aortic Aneurysms With Side Branch Coverage: Outcomes From a Prospective Single-Center Moroccan Registry.

Benjelloun Amira, Henry Michel, Taberkant Mustapha, Berrado Abdelaziz, Houati Rachid El, Semlali Abdelkader

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate endovascular repair of thoracoabdominal aortic aneurysms (TAAA) and abdominal aortic aneurysms (AAA) using the Multilayer Flow Modulator (MFM) in high-surgical-risk patients with at least one covered branch vessel.

METHODS

In this prospective single-center nonrandomized trial, 18 patients (mean age 61.1 years; 16 men) with TAAA (n=10, mean diameter 74.4 mm) and AAA (n=8, mean diameter 67.8 mm) were treated with the MFM between June 2009 and September 2012. The primary safety endpoints were all-cause mortality at 30 days and 12 months and neurological complications. The primary efficacy endpoint was overall procedure success, defined as patency of covered branch vessels, reductions in aneurysm diameter, and sac thrombus formation.

RESULTS

The technical success rate was 100% (53 study devices implanted, mean stented length 273 mm). Through mean follow-up of 13.4 months, all 61 covered branch vessels remained patent; there were no neurologic complications, ruptures, or instances of device migration, kinking, or fracture. Three patients died, 2 of unrelated causes and one of an undetermined cause. Only one reintervention with an additional MFM implanted at 5 years was required for a type I endoleak in a young patient with natural growth. Carefully planned and executed diameter and volume measurements demonstrated aneurysm shrinkage and progressive sac thrombus formation for both patient groups.

CONCLUSION

Through midterm follow-up, treatment of high-surgical-risk TAAA and AAA patients with the MFM appears to be safe and effective, maintaining branch vessel patency and reducing rupture risk through reduction of aneurysm diameter and modulation of flow dynamics. Longer term follow-up is needed.

Для цитирования: Benjelloun Amira, Henry Michel, Taberkant Mustapha, Berrado Abdelaziz, Houati Rachid El, Semlali Abdelkader. Multilayer Flow Modulator Treatment of Abdominal and Thoracoabdominal Aortic Aneurysms With Side Branch Coverage: Outcomes From a Prospective Single-Center Moroccan Registry.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2016. DOI: 10.1177/1526602816657087.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.