Complete Ipsilateral Femoral Approach Using an Iliac Branch Device to Preserve a Sole Internal Iliac Artery After Aortic Stent-Graft Placement.

Rieß Henrik Christian, Kölbel Tilo, Diener Holger, Heidemann Franziska, Debus E Sebastian, Rohlffs Fiona, Tsilimparis Nikolaos

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report implantation of an iliac branch device (IBD) for preserving antegrade blood flow to a sole internal iliac artery (IIA) via an ipsilateral approach during endovascular repair to reline an aortobi-iliac allograft.

TECHNIQUE: The technique is described in a 55-year-old man with an enteric fistula involving an aortobi-iliac Y-prosthesis. After complete excision, the prosthesis was replaced by an allograft. Due to rebleeding and resuturing of the graft, total stent-graft relining of the allograft was planned with preservation of the sole left IIA using an iliac side branch (ZBIS). During introduction of a 12-F sheath over the allograft's neobifurcation to establish a femorofemoral through-and-through approach, the allograft ruptured. A compliant balloon was inflated to control the hemorrhage. The IBD was first fully deployed, followed by stent-graft relining. Consequently, stent-graft implantation in the left IIA using a crossover maneuver was no longer feasible, so a 0.035-inch super stiff wire was introduced through the IBD's 20-F sheath. A 12-mm semi-compliant balloon was inflated in the common iliac artery above the iliac branch to act as an abutment for a 7-F sheath to run over the stiff wire into the IIA for delivery/deployment of a stent-graft.

CONCLUSION

It is feasible to use a complete ipsilateral femoral approach for IBD implantation after aortic stent-graft placement.

Для цитирования: Rieß Henrik Christian, Kölbel Tilo, Diener Holger, Heidemann Franziska, Debus E Sebastian, Rohlffs Fiona, Tsilimparis Nikolaos. Complete Ipsilateral Femoral Approach Using an Iliac Branch Device to Preserve a Sole Internal Iliac Artery After Aortic Stent-Graft Placement.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2016. DOI: 10.1177/1526602816656449.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.