MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijsu.2016.02.061

Медицинская библиотека · International journal of surgery (London, England) · 2016

Aortic valve conduit implantation in the descending thoracic aorta in a sheep model: The outcomes of pre-seeded scaffold.

Kajbafzadeh Abdol-Mohammad, Ahmadi Tafti Seyed Hossein, Mokhber-Dezfooli Mohammad-Reza, Khorramirouz Reza, Sabetkish Shabnam, Sabetkish Nastaran, Rabbani Shahram, Tavana Hamid, Mohseni Mohammad Javad

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

We evaluated the outcomes of implanting pre-seeded decellularized aortic valve conduit (AVC) with bone marrow-derived mesenchymal stem cells (MSCs) in a sheep model.

METHODS

Eight sheep AVCs were obtained under sterile conditions and decellularized by using detergent-based methods. Decellularized AVCs were seeded with autologous bone marrow-derived MSCs in a dynamic bioreactor system. Pre-seeded AVCs were implanted in the descending thoracic aorta in a sheep model. In all sheep, a decellularized pericardial patch was also anastomosed to the proximal part in order to reduce the incidence of rupture. Pathological evaluations, echocardiography, multislice computed tomography (CT), and CT angiography were performed for the evaluation of implanted AVCs.

RESULTS

The longest survival period was 19 months in pre-seeded animals with complete recellularization at the long-term follow-up. Immunohistochemical staining for desmin, smooth muscle actin, and cytokeratin was significantly positive in the pre-seeded samples and reached near normal ranges. CT angiography revealed no intimal tearing after 18 months of follow-up.

CONCLUSION

Pre-seeded AVCs with bone marrow-derived MSCs may have satisfactory results in postoperative cell seeding capabilities with promising functional potentiality. This modality may be beneficial and may provide a new era of biological grafts in cardiovascular surgery.

Для цитирования: Kajbafzadeh Abdol-Mohammad, Ahmadi Tafti Seyed Hossein, Mokhber-Dezfooli Mohammad-Reza, Khorramirouz Reza, Sabetkish Shabnam, Sabetkish Nastaran, Rabbani Shahram, Tavana Hamid, Mohseni Mohammad Javad. Aortic valve conduit implantation in the descending thoracic aorta in a sheep model: The outcomes of pre-seeded scaffold.. International journal of surgery (London, England). 2016. DOI: 10.1016/j.ijsu.2016.02.061.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.