MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2011.09.013

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2011

Establishment of chemiluminescence enzyme immunoassay for apolipoprotein B-48 and its clinical applications for evaluation of impaired chylomicron remnant metabolism.

Hanada Hiroyuki, Mugii Satomi, Okubo Manabu, Maeda Ikuhiro, Kuwayama Kazuya, Hidaka Yoh, Kitazume-Taneike Rika, Yamashita Taiji, Kawase Ryota, Nakaoka Hajime, Inagaki Miwako, Yuasa-Kawase Miyako, Nakatani Kazuhiro, Tsubakio-Yamamoto Kazumi, Masuda Daisaku, Ohama Tohru, Matsuyama Akifumi, Ishigami Masato, Nishida Makoto, Komuro Issei, Yamashita Shizuya

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Apolipoprotein B-48 (apoB-48) is a constituent of chylomicron remnants synthesized in the small intestines. The serum concentration of apoB-48 at fasting has been reported to be a marker of postprandial hyperlipidemia, a presumed risk factor for atherosclerosis.

METHODS

We evaluated the basal performance of a recently developed chemiluminescent enzyme immunoassay (CLEIA). We also examined the correlations between serum apoB-48 concentrations and other lipid concentrations or life style patterns, including smoking and drinking. We analyzed the data of 273 clinical samples by multiple regression analysis to examine the influence of other serum lipid values, age, sex, smoking, drinking status and BMI on serum apoB-48 values.

RESULTS

Within-run and between-run precision was obtained with 1.7-2.7% and 1.2-7.3%, respectively. The correlativity of enzyme-linked immunosorbent assay was correlation coefficient r=0.953, and regression y=1.02×-1.59. Serum apoB-48 concentrations were higher in males than in females, and were correlated with the status of smoking as well as with remnant-like particle-cholesterol (RLP-C) concentrations. Patients with the metabolic syndrome showed higher values of serum apoB-48 compared with control subjects.

CONCLUSION

Serum apoB-48 measurement by CLEIA was satisfactory for clinical use to assess abnormalities in the chylomicron remnant metabolism.

Для цитирования: Hanada Hiroyuki, Mugii Satomi, Okubo Manabu, Maeda Ikuhiro, Kuwayama Kazuya, Hidaka Yoh, Kitazume-Taneike Rika, Yamashita Taiji, Kawase Ryota, Nakaoka Hajime, Inagaki Miwako, Yuasa-Kawase Miyako, Nakatani Kazuhiro, Tsubakio-Yamamoto Kazumi, Masuda Daisaku, Ohama Tohru, Matsuyama Akifumi, Ishigami Masato, Nishida Makoto, Komuro Issei, Yamashita Shizuya. Establishment of chemiluminescence enzyme immunoassay for apolipoprotein B-48 and its clinical applications for evaluation of impaired chylomicron remnant metabolism.. Clinica chimica acta; international journal of clinical chemistry. 2011. DOI: 10.1016/j.cca.2011.09.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.