MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/jcma.0000000000000843

Медицинская библиотека · Journal of the Chinese Medical Association : JCMA · 2022

Pulsatility index-adjusted doppler flow measurement of pedal arteries in peripheral artery disease patients.

Li Ming-Feng, Liang Huei-Lung, Chiang Chia-Ling, Wu Tung-Ho

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

To examine the feasibility of using pulsatility index-adjusted (PI) flow equations to accurately characterize blood volume flow changes using Doppler technique in patients with peripheral artery disease (PAD) before and after percutaneous transluminal angioplasty (PTA).

METHODS

PTA was performed on 17 PAD patients (23 target vessels treated, 16 anterior tibial arteries, and 7 posterior tibial arteries). Arterial diameter, peak systolic velocity, PI, time-averaged mean velocity, and measured volume flow (MVF) of dorsalis pedis artery (DPA) and common plantar artery (CPA) were measured with duplex Doppler ultrasound before and after PTA. PI-adjusted volume flows (PIVF) were calculated as part of the MVF/PIVF relative percentage metric.

RESULTS

Significant changes (p < 0.001) of the MVF (mean: 33.0 mL/min, range: -20.9-102.2 mL/min) and MVF/PIVF relative percentages (mean: 51.8, range: 5.1-127.2%) in the DPA existed between before and after PTA, whereas no significant changes could be found in the CPA (mean:10.9 mL/min, p = 0.148 and mean: 21.3%, p = 0.146, respectively). Of the 7 treated posterior tibial arteries, the increments of the MVF/PIVF (mean: 60.4%, p = 0.033) was significant but not in the MVF (mean: 26.5 mL/min, p = 0.125). The ankle-brachial index also showed non-significant changes (p = 0.081). All PI-adjusted results matched clinical observations after blood flow restoration.

CONCLUSION

No conclusions can be drawn from the comparison of actual measured volume flow between before and after PTA. However, using the MVF/PIVF relative percentage allows for a more objective framework upon which to base clinical observations and provides clarity in situations where direct measurement provides a counter-intuitive or contradictory picture.

Для цитирования: Li Ming-Feng, Liang Huei-Lung, Chiang Chia-Ling, Wu Tung-Ho. Pulsatility index-adjusted doppler flow measurement of pedal arteries in peripheral artery disease patients.. Journal of the Chinese Medical Association : JCMA. 2022. DOI: 10.1097/jcma.0000000000000843.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.