OBJECTIVE

The objective of this study was to demonstrate that robotically assisted laparoscopy for aortic lymph node dissection was improved when double docking (DD) of the Da Vinci system is used for combined surgical procedures [defined by the combination of a pelvic procedure and a para-aortic lymphadenectomy (PAL)].

METHODS

From February 2007 to February 2013, 41 patients underwent combined procedures including PAL up to the left renal vein in 2 cancer centers. We used 2 different approaches as follows: a single docking (SD) of the Da Vinci system (transperitoneal PAL and pelvic surgery) during the first period (22 patients) and a DD during the second period (19 patients). We recorded retrospectively the lymph node count (main criteria), operative time, estimated blood loss, hospital stay, and postoperative complications.

RESULTS

We observed a statistical difference between SD and DD concerning aortic lymph node count (5.86 vs 10.89, P < 0.005). Operative time is longer in the DD group (326.1 vs 239.4 minutes, P < 0.05). No difference was observed concerning estimated blood loss. Hospital stay was longer in the DD group (4.9 vs 3.2 days, P < 0.05). Only 1 conversion to open was described in the SD group.

CONCLUSIONS

In our experience of robotically assisted laparoscopy, when PAL is combined to a pelvic procedure, the use of a DD seems to improve aortic lymph node count.Despite a longer operative time compared to SD, DD seems to be a good solution to combine the advantages of robotic assistance to our quality criteria of aortic dissection.

SYNOPSIS: We compare 2 techniques to realize robotic assisted para-aortic lymphadenectomy combined with pelvic procedure. Double docking seems to improve histological results compared to single docking.

Для цитирования: Franké Oona, Narducci Fabrice, Chereau-Ewald Elisabeth, Orsoni Marion, Jauffret Camille, Leblanc Eric, Houvenaeghel Gilles, Lambaudie Eric. Role of a double docking to improve lymph node dissection: when robotically assisted laparoscopy for para-aortic lymphadenectomy is associated to a pelvic procedure.. International journal of gynecological cancer : official journal of the International Gynecological Cancer Society. 2015. DOI: 10.1097/igc.0000000000000338.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.