MedElevator Войти в исследования
← Поиск публикаций

DOI 10.15171/jcvtr.2017.26

Медицинская библиотека · Journal of cardiovascular and thoracic research · 2017

Transcatheter heart valve in valve implantation with Edwards SAPIEN bioprosthetic valve for different degenerated bioprosthetic valve positions (First Iranian ViV report with mid-term follow up).

Haji Zeinali Ali Mohammad, Abbasi Kyomars, Saheb Jam Mohammad, Yazdani Shahrooz, Mortazavi Seyedeh Hamideh

СтатьяПеревод пока не подготовлен

Аннотация

Introduction

After early successful experience with transcatheter aortic valve replacement (TAVR), concept of transcatheter implantation of a new valve within a failing bioprosthetic valve emerged. Valve-in-valve (ViV) implantation seems to be a simpler option for high risk surgical patients.

Methods

We performed five ViV procedures in different valve positions. We included patients with failing bioprosthetic valves with high surgical risk due to concomitant comorbidities. We performed 2 transapical ViV procedures for failing mitral bioprosthetic valves, 1 transfemoral procedure for failing pulmonary valve and 2 transfemoral ViV implantation for failing tricuspid bioprosthetic valves.

Results

The procedures were successfully completed in all 5 cases with initial excellent fluoroscopic and echocardiographic verification. There was no valve embolization or paravalvular leakage in any of the cases. Transcatheter valve function was appropriate with echocardiography. Post procedural clinical adverse events like pleural effusion and transient ischemic attack were managed successfully. In midterm follow up all cases remained in appropriate functional class except from the transcatheter pulmonary valve which became moderately stenotic and regurgitant.

Conclusion

As the first Iranian all-comers case series with midterm follow up for ViV implantation, we had no mortality. Interestingly none of our patients had neurologic sequelae after the procedure. Midterm follow up for our patients was acceptable with good functional class and appropriate echocardiographic findings. Due to high surgical risk of the redo procedure after failing of a bioprosthetic valve especially in elderly patients with comorbidities, ViV implantation would be a good alternative to surgery for this high risk group.

Для цитирования: Haji Zeinali Ali Mohammad, Abbasi Kyomars, Saheb Jam Mohammad, Yazdani Shahrooz, Mortazavi Seyedeh Hamideh. Transcatheter heart valve in valve implantation with Edwards SAPIEN bioprosthetic valve for different degenerated bioprosthetic valve positions (First Iranian ViV report with mid-term follow up).. Journal of cardiovascular and thoracic research. 2017. DOI: 10.15171/jcvtr.2017.26.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.