DOI 10.1016/j.clinbiochem.2015.11.018

Медицинская библиотека · Clinical biochemistry · 2015

Evaluation of recombinant enzyme calibration to harmonize lipoprotein-associated phospholipase A2 activity results between instruments.

Cerelli Mary Jane, Grimm Karen, Duan Xiaozhu, Mulberg Edie, Jalilie Maria, Sekella Phillip, Payes Marta, Cox Heather, Blick Kenneth E, Fang Kenneth C, Zychlinsky Emi

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Enzymatic activity of lipoprotein-associated phospholipase A2 (Lp-PLA2) mediates vascular inflammation in coronary heart disease (CHD). Calibration of Lp-PLA2 activity measurements using a recombinant enzyme was performed to assess intra- and inter-laboratory assay precision and accuracy in routine clinical settings.

DESIGN AND

METHODS

Test performance assessment included recovery, analytical sensitivity, linear range, within-lab and site-to-site precision, interference, and analyte stability. Results using the Beckman-Coulter AU400 analyzer were compared to other chemistry analyzers.

RESULTS

Lp-PLA2 activity ranged from 84 to 303nmol/min/mL in 300 subjects, with 82.0% and 18.0% measurements below and at or above a cut-point of 225nmol/min/mL, respectively. Results of matched K2-EDTA plasma and serum (n=131) were similar with a slope of 1.00, y-intercept of 0.05, and R-value of 0.988. Mean recovery ranged from 90 to 106% of baseline after storage at different temperatures and time periods. Limit of detection was ≤10nmol/min/mL, without deviation from linearity between 10 and 382nmol/min/mL. Endogenous substances and medications did not interfere with the activity measurements. Overall intra- and inter-laboratory precision among three sites showed coefficients of variation of ≤3.8% and ≤5% respectively. Limit of quantitation was 1.3nmol/min/mL. Method comparison studies for multiple analyzers demonstrated slopes, intercepts or R(2) coefficients ranging from 0.96 to 1.06, -5.6 to 2.0, or 0.997 to 0.999, respectively.

CONCLUSION

Analytical performance of the calibrated PLAC(®) test for Lp-PLA2 enzyme activity assay in CHD is resistant to a wide variety of pre-analytical factors, with site-to-site reproducibility on multiple analyzers sufficient to standardize results in diverse laboratory settings.

Для цитирования: Cerelli Mary Jane, Grimm Karen, Duan Xiaozhu, Mulberg Edie, Jalilie Maria, Sekella Phillip, Payes Marta, Cox Heather, Blick Kenneth E, Fang Kenneth C, Zychlinsky Emi. Evaluation of recombinant enzyme calibration to harmonize lipoprotein-associated phospholipase A2 activity results between instruments.. Clinical biochemistry. 2015. DOI: 10.1016/j.clinbiochem.2015.11.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.