The international journal of medical robotics + computer assisted surgery : MRCAS · 2022
Robotic Heller-Dor procedure for oesophageal achalasia: Fluorescence-guided intraoperative assessment of myotomy. A retrospective single-centre experience.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Romanzi Andrea, D'Alba Lucia, Campagna Pasquale, Mancini Raffaello, Pernazza Graziano
Аннотация
BACKGROUND: The robotic Heller-Dor (RHD) procedure for oesophageal achalasia (EA) is safe and effective. We aim to evaluate the intraoperative use of fluorescence imaging, as an alternative means to intraoperative endoscopy, to assess myotomy at the end of the procedure.
METHODS: Thirty-four patients affected with EA underwent RHD. The myotomy was assessed intraoperatively by endoscopy in group A (17 patients), and by fluorescence imaging in group B (17 patients). Perioperative and long-term results were compared.
RESULTS: In group A, one mucosal tear was identified during intraoperative endoscopy. In group B, indocyanine green (ICG) helped identify residual muscle fibres in three cases. No perforation of the oesophageal mucosa occurred in group B.
CONCLUSIONS: Fluorescence-imaging improved the identification of residual muscle fibres and made it possible to verify the integrity of the mucosa without the use of intraoperative endoscopy. A significant reduction in operative times has been related to the use of this technique.
METHODS: Thirty-four patients affected with EA underwent RHD. The myotomy was assessed intraoperatively by endoscopy in group A (17 patients), and by fluorescence imaging in group B (17 patients). Perioperative and long-term results were compared.
RESULTS: In group A, one mucosal tear was identified during intraoperative endoscopy. In group B, indocyanine green (ICG) helped identify residual muscle fibres in three cases. No perforation of the oesophageal mucosa occurred in group B.
CONCLUSIONS: Fluorescence-imaging improved the identification of residual muscle fibres and made it possible to verify the integrity of the mucosa without the use of intraoperative endoscopy. A significant reduction in operative times has been related to the use of this technique.