m+Medelevator.RU
← Поиск публикаций
Korean circulation journal · 2019

Effectiveness and Safety of Zotarolimus-Eluting Stent (Resolute™ Integrity) in Patients with Diffuse Long Coronary Artery Disease.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Park Keun Ho, Ahn Youngkeun, Koh Young Youp, Ki Young Jae, Kim Sung Soo, Kim Hyun Kuk, Choi Dong Hyun, Hong Young Joon, Hwang Jin Yong, Kim Do Hoi, Rhew Jay Young, Ryu Jae Kean, Park Jong Seon, Park Tae Ho, Yang Tae Hyun, Oh Seok Kyu, Lee Bong Ryeol, Lee Seung Uk, Lee Sang Gon, Chun Kook Jin, Cho Jang Hyun, Cha Kwang Soo, Chae Jei Keon, Hur Seung Ho, Hwang Sun Ho, Park Hun Sik, Kim Doo Il

Аннотация

BACKGROUND AND OBJECTIVES: Diffuse long coronary artery disease (DLCAD) still has unfavorable clinical outcomes after successful percutaneous coronary intervention (PCI). Therefore, we aimed to evaluate the effectiveness and safety of Resolute™ zotarolimus-eluting stent (R-ZES; Resolute™ Integrity) for patients with DLCAD.

METHODS: From December 2011 to December 2014, 1,011 patients who underwent PCI using R-ZES for CAD with longer than 25 mm lesion were prospectively enrolled from 21 hospitals in Korea. We assessed the clinical outcome of major adverse cardiac events (MACE) defined as the composite of cardiac death, non-fatal myocardial infarction (MI), and clinically-driven target vessel revascularization at 12 months.

RESULTS: Mean age was 63.8±10.8 years, 701 (69.3%) patients were male, 572 (87.0%) patients had hypertension, 339 (33.8%) patients had diabetes, 549 (54.3%) patients diagnosed with acute MI and 545 (53.9%) patients had multi-vessel disease (MVD). A total of 1,697 stents were implanted into a total of 1,472 lesions. The mean diameter was 3.07±0.38 mm and the length was 28.27±6.97 mm. Multiple overlapping stents were performed in 205 (13.8%) lesions. A 12-month clinical follow-up was available in 1,004 patients (99.3%). The incidences of MACE and definite stent thrombosis at 12-month were 3.0% and 0.3% respectively. On multivariate Cox-regression analysis, multiple overlapping stents implantation, previous congestive heart failure, MVD, and age ≥75 years were independent predictors of one-year MACE.

CONCLUSIONS: Our study shows that R-ZES has an excellent 1-year clinical outcome in Korean patients with DLCAD.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты