Programmed death ligand 1 (PD-L1) PET/CT imaging to evaluate tumour saturation during atezolizumab treatment.

Hooiveld-Noeken Jahlisa S, van de Donk Pim P, Kist de Ruijter Laura, Kok Iris C, van Winkel Claudia A J, Giesen Danique, Lub-de Hooge Marjolijn N, Brouwers Adrienne H, Oosting Sjoukje F, Bensch Frederike, Smit Lotte M, Schröder Carolien P, Jalving Mathilde, Elias Sjoerd G, Gietema Jourik A, Deurloo Regula J, Williams Simon P, Ungewickell Alexander, de Groot Derk-Jan A, de Vries Elisabeth G E

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Little is known regarding tumour target saturation by the programmed death-ligand (PD-L1) antibody atezolizumab. Therefore, tumour saturation by the PD-L1 antibody atezolizumab in patients with advanced solid tumours was assessed using 89Zr-atezolizumab PET imaging.

METHODS

Patients received 10 mg 89Zr-atezolizumab after the initial 2 cycles of 1200 mg atezolizumab, followed by PET/CT scans. Tracer uptake was calculated as tumour standardized uptake value (SUV)max, normal tissues SUVmean, and tumour-to-background ratio SUVmax/SUVmax tumour. Tumour biopsies were obtained around day 7 of both cycles for autoradiography and PD-L1 immunohistochemistry. Findings were compared with previously reported pretreatment 89Zr-atezolizumab PET/CT data.

RESULTS

Geometric mean tumour SUVmax day 7 was similar between cycle 1 (5.5, 95% CI, 4.4-6.9) and 2 (5.4, 95% CI, 4.3-6.8, N = 13, P = 0.88). Geometric mean tumour-to-background ratio was 1.67 (95% CI, 1.15-2.41) and 1.53 (N = 11, 95% CI, 1.05-2.21, P = 0.32), respectively. Higher tumour-to-background ratios showed a positive trend with best overall response ptrend 0.069. Autoradiography signal was present in tumour biopsies. On-treatment uptake was lower in the lesions and spleen, with a higher blood pool SUVmean than pre-treatment.

CONCLUSIONS

Compared to earlier reported pre-treatment 89Zr-atezolizumab PET/CT results, 89Zr-atezolizumab tumour uptake during treatment is lower, suggesting partial PD-L1 tumour saturation during atezolizumab treatment.

CLINICALTRIALS: GOV: NCT02453984, NCT02478099.

Для цитирования: Hooiveld-Noeken Jahlisa S, van de Donk Pim P, Kist de Ruijter Laura, Kok Iris C, van Winkel Claudia A J, Giesen Danique, Lub-de Hooge Marjolijn N, Brouwers Adrienne H, Oosting Sjoukje F, Bensch Frederike, Smit Lotte M, Schröder Carolien P, Jalving Mathilde, Elias Sjoerd G, Gietema Jourik A, Deurloo Regula J, Williams Simon P, Ungewickell Alexander, de Groot Derk-Jan A, de Vries Elisabeth G E. Programmed death ligand 1 (PD-L1) PET/CT imaging to evaluate tumour saturation during atezolizumab treatment.. British journal of cancer. 2026. DOI: 10.1038/s41416-026-03595-8.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.