PURPOSE: The purpose of the present study was to report the temporomandibular joint (TMJ) alloplastic reconstruction (TMJR) revision and/or replacement rates and associated complication outcomes data gathered from experienced TMJ surgeons and to review the recent relevant data.

MATERIALS AND METHODS: A 21-question anonymous on-line survey was sent to all Commission on Dental Accreditation-approved oral and maxillofacial surgery program directors and to members of the European Society of TMJ Surgeons and the American Society of Temporomandibular Joint Surgeons.

RESULTS: Of the surgeons sent the survey, 22% completed the full questionnaire. Most responses were from surgeons who routinely perform TMJR surgery (93.5%). Of the respondents, 28.3% had more than 30 years of experience and 73.9% were full-time academic faculty. A total of 4638 TMJR procedures were recorded and analyzed. The incidence of TMJR revision (keeping the same device) was 3% and that of replacement (placing a new device) was 4.9%. The most common reason for revision was heterotopic ossification (27.5%). The most common reason for replacement was infection (21.1%). Revision was successful in 86.7% and replacement in 94.6% of the patients at the longest follow-up reported.

CONCLUSIONS: The data from the present study have shown that the incidence is low and the success rate is high for TMJR revision and replacement.