m+Medelevator.RU
← Поиск публикаций
The Annals of thoracic surgery · 1989

Operation for acute postinfarction mitral insufficiency using continuous oxygenated blood cardioplegia.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Panos A, Christakis G T, Lichtenstein S V, Wittnich C, el-Dalati H, Salerno T A

Аннотация

Patients with acute-onset mitral insufficiency and cardiogenic shock after myocardial infarction have a high incidence of operative death and morbidity. Patients with ventricular dysfunction, myocardial ischemia, and limited cardiac reserve undergoing an urgent operation represent a challenge to modern methods of myocardial protection. To improve results of operation a new technique was devised with continuous infusion of cold oxygenated blood cardioplegia during the entire cross-clamp period. Between 1984 and 1988, 19 consecutive patients with severe mitral regurgitation and cardiogenic shock (systolic blood pressure less than 60 mm Hg) after myocardial infarction underwent urgent myocardial revascularization, mitral valve replacement, or both. Left ventricular ejection fraction was less than 40% in 16 of 19 patients. All patients had suffered myocardial infarction within 4 weeks of operation and underwent an urgent operation within 24 hours of the onset of hemodynamic compromise. Severe three-vessel coronary artery disease was present in 16 of the 19 patients. A continuous infusion of blood cardioplegia was instituted at aortic cross-clamping and continued throughout the cross-clamp period. Infusion of continuous blood cardioplegia was also instituted through each completed distal vein graft. Myocardial septal and left ventricular apical temperatures were maintained at 10 degrees +/- 2 degrees C throughout the cross-clamp period. There were two in-hospital deaths (mortality, 10.5%) and low output syndrome was present in 10 patients (53%). At a mean follow-up of 2.5 years, there was one late death and 14 of the 16 remaining patients were in New York Heart Association functional class I or II.(ABSTRACT TRUNCATED AT 250 WORDS)

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты