MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000040003

Медицинская библиотека · Medicine · 2024

Effect of needle types and diameters using in spinal anesthesia on optic nerve sheath diameter: Prospective randomized study.

Kumaş Solak Sezen, Demirgan Serdar, Karali Elif, Selcan Ayşin

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

This prospective randomized study aimed to investigate the impact of needle types and diameters used in spinal anesthesia (SA) on optic nerve sheath diameter (ONSD) in patients undergoing lower extremity orthopedic surgery.

METHODS

Patients were randomly assigned to 3 groups based on the needle type and size used for SA: Group 25w (25 gauge Whitacre needle), Group 27q (27 gauge Quincke needle), and Group 25q (25 gauge Quincke needle). Initially, 165 patients (55 in each group) were enrolled, with 146 patients ultimately included in the analysis (Group 25w, n = 49; Group 27q, n = 48; Group 25q, n = 49). ONSD measurements were conducted using ultrasound guidance at 5 time points: T0 (pre-SA), T1 (5 minutes post-SA), T2 (5 minutes post-tourniquet inflation), T3 (5 minutes post-tourniquet deflation), and T4 (24 hours post-operation). Additionally, oxygen saturation, systolic arterial pressure, mean arterial pressure, diastolic arterial pressure, and heart rate were recorded at these time points.

RESULTS

Analysis of ONSD measurements revealed no significant differences among the groups at time points T0,T1,T2, and T4 (P = .7293, P = .4428, P = .3676, and P = .3667, respectively). However, at T3, ONSD values were significantly higher in Group 27q compared to Group 25q (P = .0325). Across all groups, the mean ONSD values measured post-tourniquet release (T3) were higher than those at T0,T2, and T4 (P < .001 for all). The incidence of nausea was similar among the groups, and no cases of headache or visual impairment were reported within the initial 24 hours post-surgery.

CONCLUSION

In conclusion, our study suggests that while subarachnoid injection and tourniquet inflation do not impact intracranial pressure (ICP), tourniquet deflation leads to an increase in ICP during lower limb surgery under SA. Therefore, caution should be exercised when using a tourniquet in patients at risk of elevated ICP.

Для цитирования: Kumaş Solak Sezen, Demirgan Serdar, Karali Elif, Selcan Ayşin. Effect of needle types and diameters using in spinal anesthesia on optic nerve sheath diameter: Prospective randomized study.. Medicine. 2024. DOI: 10.1097/md.0000000000040003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.