MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0003-4975(02)04089-4

Медицинская библиотека · The Annals of thoracic surgery · 2002

Assessment of ascending aorta using epiaortic ultrasonography during off-pump coronary artery bypass grafting.

Shimokawa Tomoki, Minato Naoki, Yamada Noriko, Takeda Yuji, Hisamatsu Yasushi, Itoh Manabu

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Use of an aortic partial clamp for proximal anastomosis during off-pump coronary artery bypass is known to increase the risk of fatal complications. The purpose of this study was to assess the management of the ascending aorta evaluated with epiaortic ultrasonography during off-pump coronary artery bypass.

METHODS

Intraoperative ultrasonography of the ascending aorta with a 10-MHz probe was performed consecutively in 155 patients undergoing off-pump coronary artery bypass between August 1999 and July 2001. The findings from ultrasonography, surgical modifications, and operative results were analyzed.

RESULTS

In 54 patients (34.8%), epiaortic ultrasonography showed atherosclerotic findings in the anterior side of the ascending aorta (group A). The remaining 101 patients had either normal findings or atherosclerotic findings in only the posterior side (group NA). A proximal anastomosis to the aorta was preoperatively planned in 117 patients (group A, 42; group NA, 75). In group A, a graft modification without clamping was implemented in 29 patients (24.8% of 117 patients), whereas the clamp site was modified to a different segment in 13 patients (11.1% of 117 patients). In all 75 patients in group NA, partial clamping was used in the standard fashion. There were no cerebral infarctions or operative deaths related to partial clamping. However, aortic dissection occurred in 1 patient in group NA.

CONCLUSIONS

In 35% of patients undergoing off-pump coronary artery bypass, epiaortic ultrasonography identified atherosclerotic findings in the anterior wall of the ascending aorta. This study suggests that revascularization without aortic manipulation during off-pump coronary artery bypass is indicated in as many as 25% of patients.

Для цитирования: Shimokawa Tomoki, Minato Naoki, Yamada Noriko, Takeda Yuji, Hisamatsu Yasushi, Itoh Manabu. Assessment of ascending aorta using epiaortic ultrasonography during off-pump coronary artery bypass grafting.. The Annals of thoracic surgery. 2002. DOI: 10.1016/s0003-4975(02)04089-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.