MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2460/ajvr.25.06.0227

Медицинская библиотека · American journal of veterinary research · 2025

Diagnostic performance of lateral flow antigen tests versus latex agglutination for cryptococcosis in dogs and cats.

Wong Samantha A, Morton John, Monteiro de Miranda Luisa, Krockenberger Mark B, Shinozaki Elissa, Malik Richard

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To investigate the diagnostic utility of 2 point-of-care cryptococcal antigen (CrAg) lateral flow assays (LFAs; Dynamiker Biotechnology Co Ltd and IMMY) for the diagnosis of cryptococcosis in dogs and cats using a latex CrAg agglutination test (Cryptococcal Antigen Latex Agglutination System; Meridian Bioscience) as the reference standard.

METHODS

Serum samples from 21 dogs and cats considered to be infected with cryptococcus and 30 animals considered unlikely to be infected were assayed using both point-of-care LFAs from January 2024 through April 2025, and sensitivity and specificity estimates were calculated.

RESULTS

The CrAg LFA (IMMY) had an estimated sensitivity of 95% (95% CI, 76.0% to 100%) and an estimated specificity of 100% (95% CI, 88.0% to 100%). The CrAg LFA (Dynamiker Biotechnology Co Ltd) had an estimated sensitivity of 100% (95% CI, 83.0% to 100%) and specificity of 20% (95% CI, 8.00% to 39.0%).

CONCLUSIONS

The CrAg LFA (IMMY) is unequivocally superior to the CrAg LFA (Dynamiker Biotechnology Co Ltd) for the screening of cryptococcosis in dogs and cats due to its vastly superior specificity.

CLINICAL RELEVANCE: The CrAg LFA (Dynamiker Biotechnology Co Ltd) in its present form should not be considered as a useful test to screen cats and dogs for cryptococcosis.

Для цитирования: Wong Samantha A, Morton John, Monteiro de Miranda Luisa, Krockenberger Mark B, Shinozaki Elissa, Malik Richard. Diagnostic performance of lateral flow antigen tests versus latex agglutination for cryptococcosis in dogs and cats.. American journal of veterinary research. 2025. DOI: 10.2460/ajvr.25.06.0227.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.