DOI 10.1097/00003246-200009000-00038
Reactive hemophagocytic syndrome presenting as a component of multiple organ dysfunction syndrome.
Аннотация
OBJECTIVE
To report two cases of severe reactive hemophagocytic syndrome (RHS), to discuss their impact, and to present evidence that RHS may be a constitutive part of multiple organ dysfunction syndrome (MODS).
DESIGN
Case-report.
SETTING
Pediatric intensive care unit (PICU).
PATIENTS: Two patients with RHS and MODS.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN
RESULTS
Case #1: A 3 yr-old boy with Mucha-Haberman syndrome (pityriasis lichenoides) was admitted to the PICU for septic shock, acute respiratory distress syndrome, capillary leak, acute renal failure, liver dysfunction, and RHS (pancytopenia and hemophagocytosis on bone marrow aspirate). The pancytopenia was severe (white blood cell count, 0.9 x 10(9)/L; hemoglobin, 59 g/L; platelets, 36 x 10(9)/L), required many transfusions, and resolved 2 months later. The patient needed mechanical ventilation for 6 wks. Length of stay in PICU was 2 months. Case #2: A previously healthy 4 yr-old girl was admitted to the PICU for respiratory failure. She developed acute respiratory distress syndrome, cardiomyopathy with complete atrioventricular block, shock, capillary leak, liver dysfunction, and RHS (pancytopenia and hemophagocytosis on bone marrow aspirate). The pancytopenia was severe (white blood cell count, 1.92 x 10(9)/L; hemoglobin, 65 g/L; platelets, 58 x 10(9)/L) and necessitated transfusional support. Serology for respiratory syncytial virus was positive. RHS duration was 20 days; the patient recovered completely. Length of mechanical ventilation was 16 days and length of stay in PICU was 3 wks.
CONCLUSIONS
These cases show that RHS may be a significant cause of pancytopenia in the PICU. It needs to be recognized as a clinical entity because it can be reversible and nonneoplastic. RHS and MODS share some pathophysiologic elements and could be related to each other.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.