Watson Laura-Jayne, Woodman Sarah H, Ganderton Deborah, Hutcheson Katherine A, Pringle Shirley, Patterson Joanne M
Аннотация
BACKGROUND: The 100 ml water swallow test (WST) is a validated swallow assessment used in head and neck cancer (HNC). We aimed to determine the level of agreement when completing the 100 ml WST via clinician-graded video-testing or patient self-testing compared to standard face-to-face assessment (FTF).
METHODS: Convenience sampling from four UK centers.
INCLUSION CRITERIA: patients with HNC treated with any modality prior to, or within 5 years of treatment. Participants were recruited to complete the 100 ml WST by video-testing or self-testing and compared with FTF.
RESULTS: Sixty-three patients were recruited; 1 was unable to perform the task; 30 in video-testing; and 32 in self-testing. There was no difference in swallow capacity (p = 0.424) and volume (p = 0.363) for the video-testing or the self-testing swallow capacity (p = 0.777) and volume (p = 0.445).
CONCLUSIONS: This study demonstrates that video-testing and self-testing are reliable methods of completing the 100 ml WST for this sample of patients with HNC.
METHODS: Convenience sampling from four UK centers.