MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/jaha.125.042937

Медицинская библиотека · Journal of the American Heart Association · 2025

Safety of Contemporary Radiation Therapy in Patients With Cardiac Implantable Electronic Devices: Implications for Clinical Practice.

Karimzad Kaveh, Shah Shalin, Kry Stephen F, Peeler Christopher, Pollard-Larkin Julianne, Koduri Amit, Chacon Portillo Martin, Chauhan Siddharth, Amatullah Atia, Miller Chase, Strang Amanda, Song Juhee, Mir Zaman Shah Khatera, Lopez Donelo, Wagner Darla, Tsai January, Vachhani Shital, Thakar Dilip, Iliescu Cezar, Durand Jean-Bernard, Dougherty Anne H, Kantharia Bharat, Deswal Anita

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Radiation therapy (RT) can cause cardiac implantable electronic device (CIED) malfunction, primarily reset. Given changes in RT and CIED technologies, large observational studies examining malfunction of contemporary CIEDs during modern-day RT are needed to guide clinical practice.

METHODS

Electronic medical records of all consecutive patients with CIEDs who underwent RT at a large tertiary cancer center between January 2015 and January 2022 were reviewed. All patients had CIED interrogation before and after completion of RT. Device-related data and RT-specific variables were collected. Statistical analyses were performed at the RT course level.

RESULTS

Over a period of 7 years, 677 patients (median age, 74 [interquartile range, 67. 8-79.2] years; 72% men) with CIEDs (498 [66%] pacemakers and 254 [34%] implantable cardioverter-defibrillators) underwent 752 courses of RT (photon, 83.5%; proton, 10.5%; electron, 6%). Only 9 patients (1.3%) underwent CIED relocation before RT. Device malfunction was observed during 8 RT courses (1.1%), primarily soft reset with data loss. All device malfunctions were observed with neutron-producing radiation (proton and photon >10 MV). CIED type (pacemaker or implantable cardioverter-defibrillator), magnetic resonance imaging conditional or nonconditional system, and radiation site (thorax or nonthorax) did not show statistical differences between RT courses with reset versus no reset. No transient signal interference or oversensing due to RT was recognized by the CIED.

CONCLUSIONS

CIED malfunction is a rare complication of contemporary RT, occurring primarily with neutron-producing radiation, most of CIED malfunction cases are without serious clinical consequences. Transient signal interference and oversensing during RT does not appear to be a clinical concern in contemporary CIEDs.

Для цитирования: Karimzad Kaveh, Shah Shalin, Kry Stephen F, Peeler Christopher, Pollard-Larkin Julianne, Koduri Amit, Chacon Portillo Martin, Chauhan Siddharth, Amatullah Atia, Miller Chase, Strang Amanda, Song Juhee, Mir Zaman Shah Khatera, Lopez Donelo, Wagner Darla, Tsai January, Vachhani Shital, Thakar Dilip, Iliescu Cezar, Durand Jean-Bernard, Dougherty Anne H, Kantharia Bharat, Deswal Anita. Safety of Contemporary Radiation Therapy in Patients With Cardiac Implantable Electronic Devices: Implications for Clinical Practice.. Journal of the American Heart Association. 2025. DOI: 10.1161/jaha.125.042937.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.