MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41393-025-01069-x

Медицинская библиотека · Spinal cord · 2025

Validity and reliability of the Turkish version of the Spinal Cord Independence Measure (SCIM III) self-report.

Soluk Özdemir Yelda, Medin Ceylan Cansın, Paker Nurdan, Korkut Veysel, Kütük Burak, Öneş Kadriye, Buğdaycı Derya, Kesiktaş Fatma N

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

STUDY

DESIGN

A cross-sectional validation study.

OBJECTIVES

The aim of the study was to create a Turkish version of the Spinal Cord Independence Measure Self-Report (SCIM-SR) scale and verify its validity and reliability.

SETTING

Rehabilitation Department at Istanbul Physical Medicine and Rehabilitation and Training Research Hospital.

METHODS

The Turkish version of SCIM-SR was translated from English using forward and backward translation in accordance with standard guidelines and 90 participants completed the SCIM-SR Turkish form. At the same time, a Spinal Cord Independence Measure III (SCIM III) was administered to the participants by a health professional through observation. Cronbach's alpha, Pearson and Spearman correlation coefficients were used to evaluate the internal consistency and concurrent validity.

RESULTS

The Cronbach's α coefficients for the total scale was 0.883. For the subscales, it was 0.929 for self-care, 0.571 for respiration and sphincter management and 0.885 for mobility. Test-retest reliability after two weeks yielded Spearman coefficients above 0.92 for the total scale and all subscales. When analyzing the correlation between SCIM-SR and SCIM III, the intraclass correlation average and its lower and upper bound values were as follows: 0.984 (0.976-0.990) for self-care; 0.970 (0.955-0.980) for respiration and sphincter management; 0.968 (0.951-0.979) for mobility and 0.980 (0.969-0.987) for the total. There was good agreement between SCIM-SR and SCIM III when evaluating the total score in Bland-Altman graphs. The Bland-Altman analysis revealed no significant proportional bias (0.76; 95% CI [-21.34, 22.87]), but a significant fixed bias was observed.

CONCLUSIONS

The Turkish version of SCIM-SR demonstrated excellent internal consistency and good validity in Turkish individuals with spinal cord injury.

Для цитирования: Soluk Özdemir Yelda, Medin Ceylan Cansın, Paker Nurdan, Korkut Veysel, Kütük Burak, Öneş Kadriye, Buğdaycı Derya, Kesiktaş Fatma N. Validity and reliability of the Turkish version of the Spinal Cord Independence Measure (SCIM III) self-report.. Spinal cord. 2025. DOI: 10.1038/s41393-025-01069-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.