MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/rcs.70108

Медицинская библиотека · The international journal of medical robotics + computer assisted surgery : MRCAS · 2025

Measuring Abdominal Skin-Surface Distances Using Photos for Perforator Mapping Analysis-A Validation Study on 3D-Printed DIEP-Flap Models.

Necker Fabian N, Cholok David J, Fischer Marc J, Gifford Kyle, Le Castillo Chris, Scholz Michael, Januszyk Michael, Leuze Christoph W, Daniel Bruce L, Momeni Arash

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

We present a novel method for accurately measuring skin-surface distances using standard smartphone photos and Photoshop, validated on 3D-printed DIEP-flap models and on calibration grid-patterns.

MATERIALS AND

METHODS

Distance measurements are acquired in Photoshop in a calibration plane between dots on a grid-pattern as well as between perforators on photos of 3D-printed models and compared against ground-truth. Margins of errors are calculated from fitted linear models.

RESULTS

Submillimeter accuracy can be achieved within errors of ±0.45 mm (80% probability) and ±0.8 mm (95% probability) for measuring distances on the dot-grid. On the 3D-printed DIEP-models, distance measurements are accurate within ±1.75 mm (80% probability) and ±3.1 mm (95% probability).

CONCLUSIONS

We introduce a simple yet highly accurate technique to measure skin-surface distances using normal photos. Depending on the scenario, submillimeter or conservatively very low millimetre errors can be achieved, sufficiently accurate for clinical use, whilst maintaining topographic relationships of the measurements.

Для цитирования: Necker Fabian N, Cholok David J, Fischer Marc J, Gifford Kyle, Le Castillo Chris, Scholz Michael, Januszyk Michael, Leuze Christoph W, Daniel Bruce L, Momeni Arash. Measuring Abdominal Skin-Surface Distances Using Photos for Perforator Mapping Analysis-A Validation Study on 3D-Printed DIEP-Flap Models.. The international journal of medical robotics + computer assisted surgery : MRCAS. 2025. DOI: 10.1002/rcs.70108.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.