Медицинская библиотека · The international journal of medical robotics + computer assisted surgery : MRCAS · 2020

An intra-operative video comparison of laparoscopic versus robotic transabdominal lateral adrenalectomy.

Gokceimam Mehmet, Akbulut Serkan, Erten Ozgun, Kahramangil Bora, Kim Yoo S, Li Pengpeng, Berber Eren

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim was to compare intraoperative conduct of adrenalectomy between laparoscopic and robotic approaches.

METHODS

Intraoperative video-recordings of patients who underwent robotic (n = 30) and laparoscopic adrenalectomy (n = 30) were analysed using Mann-Whitney U, chi-square and multivariate regression analyses.

RESULTS

Demographics, indications and outcomes were similar between groups. For all tumour sizes, camera was more engaged to surgical task and exhibited less vision problems in robotic versus laparoscopic group. There was less instrument exchange and restriction of exposure with robotic approach. For dissection, robotic approach allowed for a wider range of instrument reach around adrenal. Robotically, there was an increased ability to do fine dissection, rather than en bloc division with rigid laparoscopic vessel sealers. Bleeding problems were less robotically.

CONCLUSION

Despite similarities in post-operative morbidity and hospital stay, there was a superiority in quality of procedure performed with robotic versus laparoscopic adrenalectomy for both small and large adrenal tumours.

Для цитирования: Gokceimam Mehmet, Akbulut Serkan, Erten Ozgun, Kahramangil Bora, Kim Yoo S, Li Pengpeng, Berber Eren. An intra-operative video comparison of laparoscopic versus robotic transabdominal lateral adrenalectomy.. The international journal of medical robotics + computer assisted surgery : MRCAS. 2020. DOI: 10.1002/rcs.2203.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.