m+Medelevator.RU
← Поиск публикаций
Arthroplasty today · 2026

Bispherical Metal Augment-enabled Controllable Acetabular Distraction for Chronic Pelvic Discontinuity: Mid-term Clinical and Radiographic Outcomes of a Retrospective Single-center Case Series.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Li Guoyuan, Wang Yuhang, Luo Zhengliang, Chen Min, Zhang Xiaoqi, He Rui, Shang Xifu

Аннотация

BACKGROUND: The acetabular distraction technique utilizing porous shells and augments is effective for chronic pelvic discontinuity. We report a modified technique employing a novel bispherical augment to achieve controllable distraction and enhanced reconstruction.

METHODS: We conducted a retrospective case series of 15 consecutive revision total hip arthroplasties performed for the treatment of chronic pelvic discontinuity at a single institution between 2017 and 2021. A modular revision system of bispherical augment with a highly porous hemispherical shell was used for defect reconstruction and acetabular distraction. The mean follow-up was 5.4 years (4.0-8.1 years). Primary outcomes were implant survivorship free from aseptic loosening and radiographic healing of the discontinuity were assessed, and complications were documented.

RESULTS: One patient (6.7%) required acetabular revision for aseptic loosening at 3.5 years. One patient required bearing exchange for recurrent dislocation at 3 months postoperatively. Radiographic healing of the discontinuity was achieved in 93.3% (14/15) of hips. One asymptomatic patient had a nonprogressive radiolucent line. Mean Harris scores improved significantly from 28.6 preoperatively to 76.3 at latest follow-up (P = .002). The hip center of rotation was significantly restored inferiorly (41.5 mm-24.4 mm, P = .003) and lower limb discrepancy corrected (24 mm-5 mm, P = .012). Cumulative survival free from revision for aseptic loosening was 90.9% (95% confidence interval: 74%-100%) at mean 5.4 years. No neurovascular complications occurred.

CONCLUSIONS: The application of a bispherical augment to enable a modified, controllable acetabular distraction technique provides a reliable alternative method for reconstructing chronic pelvic discontinuity; further larger cohorts and longer follow-up are needed.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты