Аннотация

BACKGROUND

A reliable early marker is required for diagnosis of cobalamin deficiency. We calculated an appropriate holotranscobalamin (HoloTC) cut-off point for identifying cobalamin deficiency using an immunoenzymatic assay.

METHODS

Determination of the cut-off threshold and correlation between HoloTC and the other diagnostic parameters routinely used for vitamin B(12) deficiency [total vitamin B(12) (tB(12)), folate, homocysteine] were measured in 250 routine blood specimens from 107 men (mean age 59.0+/-18.8 years) and 143 women (mean age 54.2+/-23.1 years). The inclusion criterion was serum tB(12) concentration <or=221 pmol/L.

RESULTS

Analytical performance results agreed with those reported by others. A weak correlation (R=0.42) was found between HoloTC and tB(12). A 40 pmol/L cut-off threshold was chosen for HoloTC and the associated sensitivity and specificity was 0.86 and 0.66, respectively. Out of 250 tested samples, 126 showed tB(12) concentrations 139-221 pmol/L (gray zone, GZ) and 124 had tB(12) concentrations <139 pmol/L (low, L). Values less than the cut-off for HoloTC were present in 68.2% and 37.9% of cases in the GZ and L group, respectively (p<0.01), and in 53.2% of subjects.

CONCLUSIONS

Our results confirmed the analytical reliability of the AxSYM HoloTC assay. The method is adequate for routine use and a cut-off threshold of 40 pmol/L is appropriate for assessing cobalamin deficiency in populations with reduced tB(12) values.

Для цитирования: Bamonti Fabrizia, Moscato Giovanna Antonella, Novembrino Cristina, Gregori Dario, Novi Claudia, De Giuseppe Rachele, Galli Claudio, Uva Valentina, Lonati Silvia, Maiavacca Rita. Determination of serum holotranscobalamin concentrations with the AxSYM active B(12) assay: cut-off point evaluation in the clinical laboratory.. Clinical chemistry and laboratory medicine. 2010. DOI: 10.1515/cclm.2010.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.