Automated O2 Titration Alone or With High-Flow Nasal Cannula During Walking Exercise in Chronic Lung Diseases.

СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vézina Felix-Antoine, Bouchard Pierre-Alexandre, Breton-Gagnon Émilie, Dion Geneviève, Viglino Damien, Roy Pascalin, Bilodeau Lara, Provencher Steeve, Denault Marie-Hélène, Saey Didier, Lellouche François, Maltais François

Аннотация

BACKGROUND: Exercise-induced O2 desaturation contributes to dyspnea and exercise intolerance in various respiratory diseases. This study assessed whether automated O2 titration was superior to fixed-flow O2 to improve exertional dyspnea and walking exercise endurance. We also aimed at evaluating possible additive effects of high-flow nasal cannula coupled with automated O2 titration on these outcomes.

METHODS: Subjects with chronic respiratory diseases and exercise-induced desaturation performed a 3-min constant-speed shuttle test (CSST) and an endurance shuttle walking test (ESWT) with either (1) fixed-flow O2, (2) automated O2 titration targeting an SpO2 of 94% (± 2%), and (3) automated O2 titration + high-flow nasal cannula according to a randomized sequence. The main outcome was Borg dyspnea score at the end of the 3-min CSST. Secondary outcomes included endurance time and dyspnea during ESWT and oxygenation status during exercise.

RESULTS: Ten subjects with COPD, 10 with interstitial lung disease, 5 with pulmonary hypertension, and 3 with cystic fibrosis completed the study. Compared to fixed-flow O2, automated O2 titration did not reduce dyspnea at the end of the 3-min CSST. Endurance time during the ESWT was prolonged with automated O2 titration (mean difference 298 [95% CI 205-391] s, P < .001), and dyspnea at isotime was reduced. No further improvement was noted when high-flow nasal cannula was added to automated O2 titration. Compared to fixed-flow O2, O2 flows were higher with automated O2 titration, resulting in better oxygenation.

CONCLUSIONS: Automated O2 titration was superior to fixed-flow O2 to alleviate dyspnea and improve exercise endurance during the ESWT in subjects with a variety of chronic respiratory diseases. Adding high-flow nasal cannula to automated O2 titration provided no further benefits.