A robust volumetric arc therapy planning approach for breast cancer involving the axillary nodes.

Письмо в редакциюРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

van der Veen Gijs J, Janssen Tomas, Duijn Amber, van Kranen Simon, de Graaf Rob J, Wortel Geert, Wiersma Terry G, Damen Eugène

Аннотация

We quantify the robustness of a proposed volumetric-modulated arc therapy (VMAT) planning and treatment technique for radiotherapy of breast cancer involving the axillary nodes. The proposed VMAT technique is expected to be more robust to breast shape changes and setup errors, yet maintain the improved conformity of VMAT compared to our current standard technique that uses tangential intensity-modulated radiation therapy (IMRT) fields. Treatment plans were created for 10 patients. To account for anatomical variation, planning was carried out on a computed tomography (CT) with an expanded breast, followed by segment weight optimization (SWO) on the original planning CT (VMAT + SWO). For comparison purposes, tangential field IMRT plans and conventional VMAT (cVMAT) plans were also created. Anatomical changes (expansion and contraction of the breast) and setup errors were simulated to quantify changes in target coverage, target maximum, and organ-at-risk (OAR) doses. Finally, robustness was assessed by calculating the actual delivered dose for each fraction using cone-beam CT images acquired during treatment. Target coverage of VMAT + SWO was shown to be significantly more robust compared to cVMAT technique, against anatomical variations and setup errors. Sensitivity of the clinical target volume (CTV) V95% is -5%/cm of expansion for the proposed technique, which is identical to the IMRT technique and much lower than the -22%/cm for cVMAT. Results are similar for setup errors. OAR doses are mostly insensitive to anatomical variations and the OAR sensitivity to setup variations does not depend on the planning technique. The results are confirmed by dose distributions recalculated on cone-beam CT, showing that for VMAT + SWO the CTV V95% remains within 2.5% of the planned value, whereas it deviates by up to 7% for cVMAT. A practical VMAT planning technique is developed, which is robust to daily anatomical variations and setup errors.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты