World journal of surgical oncology · 2018
Application of a carbon nanoparticle suspension for sentinel lymph node mapping in patients with early breast cancer: a retrospective cohort study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zhang Liulu, Huang Yijie, Yang Ciqiu, Zhu Teng, Lin Yufeng, Gao Hongfei, Yang Mei, Cheng Minyi, Wang Kun
Аннотация
BACKGROUND: To stage axillary lymph nodes in women with early-stage breast cancer, sentinel lymph node biopsy (SLNB), rather than axillary lymph node dissection (ALND), has been employed. Moreover, different tracer methods have various advantages and disadvantages. In recent years, carbon nanoparticle suspensions (CNSs) have been used as lymph node tracers during surgeries for thyroid cancer, gastric cancer, and colorectal cancer. The study retrospectively analyzed the feasibility and accuracy of CNS for sentinel lymph node (SLN) mapping in patients with early breast cancer.
METHODS: This single-center, retrospective study included breast cancer patients who underwent SLNB from January 1, 2016, to December 31, 2017, in the Department of Breast Cancer, Guangdong General Hospital. All patients received standard SLNB surgery using a CNS tracer.
RESULTS: A total of 332 cases were included in this study. The SLN identification rate was 99.1% (329/332), and the mean number of SLNs was 2.6 (range, 1-6). SLN metastasis was found in 62 (18.8%) cases, of which 90.3% were found to be macrometastases. The sensitivity of SLNB was 95.9% (47/49), with a specificity of 100% (42/42), a positive predictive value of 100% (47/47), a negative predictive value of 95.5% (42/44), and a false-negative rate of 4.1% (2/49).
CONCLUSION: The identification and predictive values of a CNS tracer for SLNB were satisfactory.
METHODS: This single-center, retrospective study included breast cancer patients who underwent SLNB from January 1, 2016, to December 31, 2017, in the Department of Breast Cancer, Guangdong General Hospital. All patients received standard SLNB surgery using a CNS tracer.
RESULTS: A total of 332 cases were included in this study. The SLN identification rate was 99.1% (329/332), and the mean number of SLNs was 2.6 (range, 1-6). SLN metastasis was found in 62 (18.8%) cases, of which 90.3% were found to be macrometastases. The sensitivity of SLNB was 95.9% (47/49), with a specificity of 100% (42/42), a positive predictive value of 100% (47/47), a negative predictive value of 95.5% (42/44), and a false-negative rate of 4.1% (2/49).
CONCLUSION: The identification and predictive values of a CNS tracer for SLNB were satisfactory.