CRISPR/Cas12a Integrated with a Microfluidic System Enhanced Analysis of Programmed Cell Death Ligand 1 Expression in Circulating Tumor Cells from Non-Small Cell Lung Cancer Patients.

Zeng Bingjie, Sheng Anzhi, Zhang Xiao, Wang Xianzhao, Bao Yunxia, Huang Yiwen, Huang Yiman, Shan Liang, Xu Xin, Qin Yueyang, Yang Yiran, Deng Yiran, Tian Ling, Wang Jiayi, Ma Lifang

СтатьяПеревод пока не подготовлен

Аннотация

The detection of programmed cell death ligand 1 (PD-L1) positive circulating tumor cells (CTCs) in peripheral blood has significant clinical value for predicting and evaluating the efficacy of immunotherapy in patients with non-small cell lung cancer (NSCLC). However, traditional methods remain limited by low sensitivity and the precise quantification remains a challenge. A dual-mode microfluidic analysis chip was constructed here that included clustered regularly interspaced short palindromic repeats/Cas12a quantification and immunofluorescence visualization. Quantification of the PD-L1 protein on the surface of CTCs (20 to 107 cell/mL) was achieved selectively and sensitively by amplifying the nucleic acid target to generate a strong fluorescent signal, even with very low levels of target cells. The system effectively detected PD-L1+ CTCs expression in peripheral blood samples from patients with NSCLC and monitored the efficacy of PD-1/PD-L1 targeted immune checkpoint inhibitors in real time. It exhibited excellent performance for clinical applications in monitoring the prognosis in patients with NSCLC.

Для цитирования: Zeng Bingjie, Sheng Anzhi, Zhang Xiao, Wang Xianzhao, Bao Yunxia, Huang Yiwen, Huang Yiman, Shan Liang, Xu Xin, Qin Yueyang, Yang Yiran, Deng Yiran, Tian Ling, Wang Jiayi, Ma Lifang. CRISPR/Cas12a Integrated with a Microfluidic System Enhanced Analysis of Programmed Cell Death Ligand 1 Expression in Circulating Tumor Cells from Non-Small Cell Lung Cancer Patients.. ACS sensors. 2025. DOI: 10.1021/acssensors.5c01152.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.