m+Medelevator.RU
← Поиск публикаций
Gastrointestinal endoscopy · 2014

Macroscopic on-site quality evaluation of biopsy specimens to improve the diagnostic accuracy during EUS-guided FNA using a 19-gauge needle for solid lesions: a single-center prospective pilot study (MOSE study).

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Iwashita Takuji, Yasuda Ichiro, Mukai Tsuyoshi, Doi Shinpei, Nakashima Masanori, Uemura Shinya, Mabuchi Masatoshi, Shimizu Masahito, Hatano Yuichiro, Hara Akira, Moriwaki Hisataka

Аннотация

BACKGROUND: Although rapid on-site cytologic evaluation provides high efficacy of EUS-guided FNA (EUS-FNA), its availability is limited. Alternatively, macroscopic on-site quality evaluation (MOSE) may increase the efficacy of EUS-FNA.

OBJECTIVE: To assess the efficacy of MOSE in estimating the adequacy of histologic core specimens obtained by EUS-FNA using a standard 19-gauge needle (19GN) for solid lesions.

DESIGN: A prospective pilot study.

SETTING: Tertiary-care referral center.

PATIENTS: One hundred patients with solid lesions (n = 111 lesions).

INTERVENTIONS: EUS-FNA using 19GN MAIN OUTCOME MEASUREMENTS: The relation of a macroscopic visible core (MVC) in the FNA specimens on MOSE with histologic core and the diagnostic yields were studied.

RESULTS: The feasibility of EUS-FNA using a 19GN was 99%. The final diagnoses were malignancy in 83 lesions and benign in 28. MOSE revealed MVC in 91.1% with the median length of 8 mm. Histologic core was confirmed in 78.9%. The receiver-operating characteristic curve of the length of MVC for the presence of histologic core showed the cut-off MVC length of 4 mm with area under the curve of .893. Comparisons of per-pass diagnostic yields showed significantly superior histologic, cytologic, and overall diagnostic yields in MVC ≥ 4 mm as compared with <4 mm. The multivariate analysis for false-negative pass identified lesion in the pancreas and MVC < 4 mm as significant risk factors. No adverse events were seen.

LIMITATIONS: Single center, limited operators

CONCLUSION: MVC of ≥4 mm on MOSE can be an indicator of specimen adequacy and can improve diagnostic yield; however, additional FNA may be recommended for pancreatic lesions. (

CLINICAL TRIAL REGISTRATION NUMBER: UMIN000010417.).

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты