MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12149-014-0925-7

Медицинская библиотека · Annals of nuclear medicine · 2014

Cardiac blood pool activity on postablation radioiodine imaging.

Aktaş Ayşe, Kocabaş Beyza, Erhamamci Seval, Gençoğlu Arzu, Liman Cevdet

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

There are reports on physiologic and pathologic mediastinal uptake on radioiodine imaging in patients with thyroid carcinoma. The most commonly reported physiologic causes of mediastinal uptake are esophageal retention of salivary secretion and uptake by hyperplastic or normal thymus gland. In this study, we evaluated physiologic cardiac blood pool (CBP) activity and its associated findings on radioiodine imaging.

METHODS

Cardiac blood pool activity was evaluated in 186 postablation and 32 posttherapy scans. After oral radioiodine administration, imaging was initiated on day 7. Thyroglobulin, anti-thyroglobulin and TSH blood level determination was carried out in all patients. Whole-body scans were inspected with regard to residual thyroid uptake, esophageal uptake, CBP activity, hepatic activity and metastatic iodine uptake. Uptake in the residual thyroid tissue was graded visually as mild (m), moderate (M) and significant (S). Whenever CBP activity was detected on visual inspection, its intensity was graded as mild (1), moderate (2), and significant (3).

RESULTS

Cardiac blood pool activity was detected in 61 postablation scans (33 %). Residual thyroid uptake was observed in all patients with CBP. A significant correlation existed between the intensity of uptake and the presence of CBP (p < 0.05). The mean Tg in patients with CBP was significantly higher than those without CBP (p < 0.05). Cardiac blood pool activity was not observed in any posttherapy scans and in those scans with distant metastases in the postablation group. Linear or irregular activity pattern thought to be due to esophagus was detected in 4 % of postablation scans.

CONCLUSIONS

The results have revealed CBP to be common on postablation scans. Its presence correlated with the intensity of residual thyroid uptake and had a significant association with increased thyroglobulin levels. Its absence on posttherapy scans despite increased Tg levels suggested that this activity is due to labeled thyroid hormones released by the residual thyroid tissue. Its presence might imply a high level of blood radiation dose.

Для цитирования: Aktaş Ayşe, Kocabaş Beyza, Erhamamci Seval, Gençoğlu Arzu, Liman Cevdet. Cardiac blood pool activity on postablation radioiodine imaging.. Annals of nuclear medicine. 2014. DOI: 10.1007/s12149-014-0925-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.