A Comparison of Different Transfer Techniques in Evaluating Specimen Adequacy in FNAB: An Unexplored Topic.

Karagülle Mehmet, Arslan Fatma Zeynep, Ozcan Burcu, Gedik Arzu Algun

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

This study compared two conventional smear methods during FNAB: The method where the green part of the syringe is touched to the slide (Technique 1) and the method where the contents are rapidly sprayed (Technique 2). We investigated differences in specimen adequacy, diagnostic outcomes, and variations among pathological subgroups.

METHODS

FNAB was performed on 128 lesions from 119 patients, and the samples were classified according to the Bethesda System. The two transfer techniques were compared in terms of cell count and diagnostic results.

RESULTS

Of the 128 lesions, 93 were diagnosed as adenomatous nodules. No significant difference was found in the nondiagnostic result rates between the methods. The p-value was found to be 0.65. The average cell count in Technique 1 was 1.95 (min: 0, max: 3+, SD: 1.03), while in Technique 2 it was 1.91 (min: 0, max: 3+, SD: 1.07). Although Technique 1 resulted in a slightly higher positive cell detection, the two techniques were not superior to each other in terms of cell count. The p-value was found to be 0.87. When both techniques were used together, more diagnoses could be made in more patients compared to when each technique was used separately. However, statistically, the combined use of both techniques was not superior to Technique 1 (p = 0.16) or Technique 2 (p = 0.083).

CONCLUSION

Both techniques showed similar nondiagnostic rates. Technique 1 resulted in a slight increase in the average positive cell count, whereas Technique 2 may be preferred due to its simplicity and safety. It was also found that neither technique provided a clear superiority over the other, and using both techniques together was not superior to either Technique 1 or Technique 2. In determining standard FNAB procedures and improving diagnostic accuracy, factors such as nodule characteristics and needle caliber, along with smear techniques, should also be considered. Larger-scale studies are necessary to validate these findings and improve FNAB practices.

Для цитирования: Karagülle Mehmet, Arslan Fatma Zeynep, Ozcan Burcu, Gedik Arzu Algun. A Comparison of Different Transfer Techniques in Evaluating Specimen Adequacy in FNAB: An Unexplored Topic.. Diagnostic cytopathology. 2025. DOI: 10.1002/dc.25458.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.