m+Medelevator.RU
← Поиск публикаций
Diabetes care · 2003

Utility of B-type natriuretic peptide (BNP) as a screen for left ventricular dysfunction in patients with diabetes.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Epshteyn Victoria, Morrison Katherine, Krishnaswamy Padma, Kazanegra Radmila, Clopton Paul, Mudaliar Sunder, Edelman Steven, Henry Robert, Maisel Alan

Аннотация

OBJECTIVE: Routine screening of diabetic patients with echocardiography is not feasible due to its limited availability and high cost. B-type natriuretic peptide (BNP) is secreted from the left ventricle in response to pressure overload and is elevated in both systolic and diastolic dysfunction.

RESEARCH DESIGN AND METHODS: BNP levels were compared to echocardiographic findings in 263 patients. Patients were divided into two groups: clinical indication for echocardiography (CIE) (n = 172) and those without clinical indication for echocardiography (no-CIE) (n = 91). Cardiologists making the assessment of left ventricular function were blinded when measuring plasma levels of BNP.

RESULTS: The 91 patients with no-CIE with echoes had similar BNP levels (83 +/- 16 pg/ml) to the 215 patients with no-CIE without echoes (63 +/- 10, P = 0.10). Patients with CIE and subsequent abnormal left ventricular function (n = 112) had a mean BNP concentration of 435 +/- 41 pg/ml, compared with those with no-CIE, but had abnormal left ventricular function on echo (n = 32) (161 +/- 40 pg/ml). Twenty-one of 32 patients with no-CIE but with abnormal left ventricular function had diastolic dysfunction (BNP 190 +/- 60 pg/ml). A receiver-operating characteristic (ROC) curve revealed that the area under the curve was 0.91 for CIE patients and 0.81 for no-CIE patients (P < 0.001). For those with no congestive heart failure (CHF) symptoms, BNP levels showed a high negative predictive value (91% for BNP values <39 pg/ml), while in those patients who had a CIE, BNP levels showed a high positive predictive value for the detection of left ventricular dysfunction (96% with BNP levels >90 pg/ml).

CONCLUSIONS: BNP can reliably screen diabetic patients for the presence or absence of left ventricular dysfunction.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты