MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0034-1399545

Медицинская библиотека · RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin · 2015

Thoracic Pathologies on Scout Views and Bolus Tracking Slices for Computed Tomographic Cerebral Angiography.

Groth M, Fiehler J, Henes F O, Buhk J H

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the incidence of additional thoracic pathologic findings (TPF) detected on scout views and corresponding bolus tracking slices (SVBT) for computed tomographic cerebral angiography (CTCA) and to test the reliability and accuracy of these findings.

MATERIALS AND

METHODS

The study collective included 505 consecutive patients who underwent multidetector CTCA. Appendant SVBT of all patients were reviewed for any pathologic findings and patient medical reports were analyzed, if any medical treatment was initiated for the detected pathologic findings. In 18 patients thoracic CT scans were performed in the same session. These were additionally reviewed by two blinded observers to test for intra- and interobserver reliability as well as for accuracy of detecting thoracic pathologies on SVBT.

RESULTS

TPF were detected in 165 (33%) SVBT. The five most common pathologic findings were: pleural effusion, 12%; pneumonia, 8%; atelectasis/dystelecatsis, 6%; pericardial effusion, 2% and elevated diaphragm, 1%. For 48 % of these findings medical treatment was initiated. SVBT showed a sensitivity of 53%, a specificity of 99%, a positive predictive value of 89%, a negative predictive value of 94% and accuracy of 94% for the detection of TPF. The intraobserver reliability was very good and the interobserver reliability showed moderate agreement.

CONCLUSION

SVBT for CTCA should be reviewed with care by radiologists, since additional TPF can affect patient management. Nevertheless, despite a high specificity of SVBT for detecting TPF, an only moderate sensitivity has to be taken into account.

KEY POINTS: Thoracic pathologies are frequently found on scout views for cerebral CTA. Reviewing additional bolus trigger slices will improve diagnostic sensitivity. Despite high specificity, scout views and trigger slices offer a moderate sensitivity. Evaluation of scout views and trigger slices can result in medical treatment.

Для цитирования: Groth M, Fiehler J, Henes F O, Buhk J H. Thoracic Pathologies on Scout Views and Bolus Tracking Slices for Computed Tomographic Cerebral Angiography.. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2015. DOI: 10.1055/s-0034-1399545.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.